7
180R9262 / IOM APP 0.6-1.0 Appendices - v02 / 12.2012
Data sheet
APP 0.6-1.0
The power requirements can be determined
using one of the following guiding equations:
6.
Power requirements
Pump
model
Flow
Pressure
rpm
Calc.
factor
60 bar
70 bar
80 bar
l/min
m
3
/h
gpm
870 psi
1015 psi
1160 psi
APP 0.6
10.2
0.61
2.69
1.38 kW
1.61 kW
1.84 kW
2840
475.8
APP 0.6
12.3
0.74
3.25
1.66 kW
1.94 kW
2.21 kW
3400
475.8
APP 0.8
13.6
0.82
3.61
1.73 kW
2.02 kW
2.31 kW
2840
475
APP 0.8
16.3
0.98
4.31
2.07 kW
2.41 kW
2.76 kW
3400
475
APP 1.0
16.5
0.99
4.37
2.14 kW
2.49 kW
2.85 kW
2840
474.6
APP 1.0
19.8
1.19
5.24
2.57 kW
2.99 kW
3.42 kW
3400
474.6
l/min x bar
16.7 x m3/h x bar
0.26 x gpm x psi
Required power =
[kW] or
[kW] or
[kW]
Calc. factor
Calc. factor
Calc. factor
1 hp
= 0.75 kW
1 kW
= 1.34 hp
1 gpm = 3.79 l/min
1 l/min = 0.26 gpm
1 m
3
/h = 4.40 gpm
1 gpm = 0.23 m
3
/h
7.
Temperature and
corrosion
7.1
Operation
The chart below illustrates the corrosive
resistance of di
ff
erent types of stainless steel
related to NaCl concentration and temperature.
All critical parts of the APP water pump is made
of Super Duplex.
If the water pump is operated at high salinity,
always
fl
ush the water pump with fresh water at
operation stop in order to minimize the risk of
crevice corrosion.
316L
Super Duplex
80 º
C
70
60
50
40
30
20
100
160
1600
1000
16000
10 000
160000
100 000
CI -
ppm
NaCI
ppm
Duplex
Fluid temperature:
+2° C to +50° C (+35.6° F to 122° F) - dependent
on the NaCl concentration
Ambient temperature:
+2° C to +50° C (+35.6° F to 122° F)
Содержание APP 1.0
Страница 5: ...5 180R9262 IOM APP Pumps v01 12 2012 EU Declaration of Conform ity...
Страница 53: ...6 Trouble shooting guide Guideline Trouble shooting guide for APP pumps MAKING MODERN LIVING POSSIBLE...
Страница 69: ...User manual Appendices for IOM APP Pumps APP 0 6 1 0 51 180R9262 IOM APP 0 6 1 0 Appendices v02 12 2012...