6
180R9262 / IOM APP 0.6-1.0 Appendices - v02 / 12.2012
Data sheet
APP 0.6-1.0
Furthermore, this diagram shows that the
fl
ow
can be changed by changing the rotation speed
of the pump. The
fl
ow/rpm ratio is constant, and
the “required “
fl
ow can be obtained by changing
the rotation speed to a corresponding value.
Thus, the required rpm can be determined as:
4.
Flow at di
ff
erent rpm
Using the diagram shown below, it is easy to
select the pump which
fi
ts the application best if
the
fl
ow required and the rotation speed (rpm) of
the pump are known.
0
0,2
0,4
0,6
0,8
1
1,2
1,4
0
500
1000
1500
2000
2500
3000
3500
rpm
m
3
/h
APP 1.0
APP 0.8
APP 0.6
Required
fl
ow
×
Rated rpm
Required rpm =
Rated
fl
ow
5.
Flushing valve
The diagram shows pressure di
ff
erence across
fl
ushing valve:
APP0.6-1.0 flushing valve characteristic
0
2
4
6
8
10
12
14
16
18
0
1
2
3
4
5
Pressure [bar]
F
lo
w[
l/m
in]
flow[l/min]
APP 0.6-1.0 Flushing valve characteristic
Содержание APP 1.0
Страница 5: ...5 180R9262 IOM APP Pumps v01 12 2012 EU Declaration of Conform ity...
Страница 53: ...6 Trouble shooting guide Guideline Trouble shooting guide for APP pumps MAKING MODERN LIVING POSSIBLE...