102
RS8HP102 © Danfoss 2018-09
AK-CC 750A
Appl.
type
No.
of
AKV
Def.
type
Air
sensor
Controller - (Module no. 1 point 1-19)
Module 2
App.no at set-
ting via AKM or
display
AI1
AI2 AI3
AI4
AI5
AI6
AI7
AI8
AI9
AI10
AI11
DO1
DO2
DO3
DO4
DO5
DO6
DO7
DO8
AI1
AI2
AI3
AI4
AI5
AI6
AI7
AI8
DO1
DO2
DO3
DO4
DO5
DO6
pt1
pt2 pt3
pt4
pt5 pt6 pt 7 pt8 pt 9
pt10
pt 11 pt 12
pt 13
pt 14
pt 15
pt 16
pt 17
pt 18
pt 19
High
temp.
Low
temp.
Room
1
Air
S3A + S4A S2A
S3A S4A
Door
Po
AKV A
Rail heat
Light
Fan
6
EL
S3A + S4A S2A
S3A S4A
S5A
Door
Po
AKV A Def.
Rail heat
Light
Fan
7
8
Gas
S3A + S4A S2A
S3A S4A
S5A
Door
Po
AKV A Def.
Suction Drain
Rail heat
Light
Fan
9
10
2
Air
S3A + S4A S2A
S3A S4A
S2B
Door
Po
AKV A AKV B
Rail heat
Light
Fan
16
EL
S3A + S4A S2A
S3A S4A
S5A
S2B
S5B
Door
Po
AKV A AKV B Def. A
Def. B
Rail heat
Light
Fan
17
18
Gas
S3A + S4A S2A
S3A S4A
S5A
S2B
S5B
Door
Po
AKV A AKV B Def. A
Def. B
Suction Drain
Light
Fan
19
20
3
Air
S3A + S4A S2A
S3A S4A
S2B
S2C
Door
Po
AKV A AKV B AKV C
Rail heat
Light
Fan
26
EL
S3A + S4A S2A
S3A S4A
S5A
S2B
S5B
S2C
S5C
Door
Po
AKV A AKV B AKV C
Def. A
Def. B
Def. C
Light
Fan
27
28
Gas
S3A + S4A S2A
S3A S4A
S5A
S2B
S5B
S2C
S5C
Door
Po
AKV A AKV B AKV C
Def. A
Def. B
Def. C
Suction Drain
Rail heat Light
Fan
29
30
4
Air
S3A + S4A S2A
S3A S4A
S2B
S2C
S2D
Door
Po
AKV A AKV B AKV C
AKV D
Rail heat
Light
Fan
36
EL
S3A
S2A
S3A S5A
S2B
S5B
S2C
S5C
S2D
S5D
Door
Po
AKV A AKV B AKV C
AKV D
Def. A
Def. B
Def. C
Def. D
Rail heat Light
Fan
37
38
Gas
S3A
S2A
S3A S5A
S2B
S5B
S2C
S5C
S2D
S5D
Door
Po
AKV A AKV B AKV C
AKV D
Def. A
Def. B
Def. C
Def. D
Rail heat Light
Fan
Suction
Drain
39
40
Case
1
Air
S3 +S4
S2A
S3A S4A
Clean
Blinds Po
AKV A
Blinds
Rail heat
Light
Fan
1
EL
S3 + S4
S2A
S3A S4A
S5A
Clean
Blinds Po
AKV A Def.
Blinds
Rail heat
Light
Fan
2
3
Gas
S3 + S4
S2A
S3A S4A
S5A
Clean
Blinds Po
AKV A Def.
Suction Drain
Blinds
Rail heat
Light
Fan
4
5
2
Air
S3 + S4
S2A
S3A S4A
S2B
S3B
S4B
Clean
Blinds Po
AKV A AKV B
Blinds
Rail heat
Light
Fan
11
EL
S3 + S4
S2A
S3A S4A
S5A
S2B
S3B
S4B
S5B
Clean
Blinds Po
AKV A AKV B Def. A
Def. B
Blinds
Rail heat
Light
Fan
12
13
Gas
S3 + S4
S2A
S3A S4A
S5A
S2B
S3B
S4B
S5B
Clean
Po
AKV A AKV B Def. A
Def. B
Suction Drain
Light
Fan
14
15
3
Air
S3 + S4
S2A
S3A S4A
S2B
S3B
S4B
S2C
S3C
S4C
Blinds Po
AKV A AKV B AKV C
Blinds
Rail heat
Light
Fan
21
EL
S3 + S4
S2A
S3A S4A
S5A
S2B
S3B
S4B
S5B
Clean
Po
AKV A AKV B AKV C
Def. A
Def. B
Def. C
Light
Fan
S2C
S3C
S4C
S5C
22
23
Gas
S3 + S4
S2A
S3A S4A
S5A
S2B
S3B
S4B
S5B
Clean
Blinds Po
AKV A AKV B AKV C
Def. A
Def. B
Def. C
Suction Drain
S2C
S3C
S4C
S5C
Rail heat Light
Fan
Blinds
24
25
4
Air
S3 + S4
S2A
S3A S4A
S2B
S3B
S4B
Clean
Blinds Po
AKV A AKV B AKV C
AKV D
Blinds
Rail heat
Light
Fan
S2C
S3C
S4C
S2D
S3D
S4D
31
EL
S3 + S4
S2A
S3A S4A
S5A
S2B
S3B
S4B
S5B
Clean
Blinds Po
AKV A AKV B AKV C
AKV D
Def. A
Def. B
Def. C
Def. D
S2C
S3C
S4C
S5C
S2D
S3D
S4D
S5D
Rail heat Light
Fan
Blinds
32
33
Gas
S3 + S4
S2A
S3A S4A
S5A
S2B
S3B
S4B
S5B
Clean
Blinds Po
AKV A AKV B AKV C
AKV D
Def. A
Def. B
Def. C
Def. D
S2C
S3C
S4C
S5C
S2D
S3D
S4D
S5D
Rail heat Light
Fan
Blinds
Suction
Drain
34
35
Function
The controller has a setting where you can choose between various
types of installation. If you use these settings, the controller will
suggest a series of connection points for the different functions.
These points are shown below.
Even if your installation is not 100% as described below, you can
still use the function. After use, you need only adjust the divergent
settings.
The given connection points in the controller can be changed if you
wish.
Appendix - Recommended
connection Group 2
AKV valves