Danfoss AK-CC 460 Скачать руководство пользователя страница 3

 

AK-CC 

460 

Instructions RI8SE202 © Danfoss 07/2017 

3

Coordinated defrost via 
data communication

Coordinated defrost via 
cable connections

The following controllers can be connected 
up in this way:
EKC 204A, AK-CC 210, AK-CC 250, 
AK-CC 450, AK-CC 460, AK-CC 550,

Refrigeration is resumed when all 
controllers have “released” the signal for 
defrost.

The setting of controllers to coordinate 
their defrosting takes place in the 
gateway/system manager.

Refrigeration is resumed when all 
controllers have “released” the signal for 
defrost.

DO6

Light relay

There is connection between terminal 17 and 18 when the 
light must be on.

DO7

Rail heat

There is connection between terminal 20 and 21 when the rail 
heat is on.

DI3

Digital input signal

Safety circuits compressor 1 and 2
The signal must have a voltage of 0 / 230 V a.c. 

Data communication
If data communication is used, it is important that the installation 
of the data communication cable is performed correctly.
See separate literature No. RC8AC…

Electric noise
Cables for sensors, DI inputs and data communication must be 
kept separate from other electric cables:
- Use separate cable trays
- Keep a distance between cables of at least 10 cm
- Long cables at the DI input should be avoided

Installation considerations
Accidental damage, poor installation, or site conditions, can give 
rise to malfunctions of the control system, and ultimately lead to a 
plant breakdown.
Every possible safeguard is incorporated into our products to 
prevent this. However, a wrong installation, for example, could still 
present problems. Electronic controls are no substitute for normal, 
good engineering practice.
Danfoss wil not be responsible for any goods, or plant 
components, damaged as a result of the above defects. It is the 
installer's responsibility to check the installation thoroughly, and 
to fit the necessary safety devices.
Special reference is made to the necessity of signals to the 
controller when the compressor is stopped and to the need of 
liquid receivers before the compressors.
Your local Danfoss agent will be pleased to assist with further 
advice, etc.
 

max. 10

Содержание AK-CC 460

Страница 1: ...Principle Dimensions Instructions AK CC 460 RI8SE202 07 2017 Identification 084B8016 1...

Страница 2: ...her RJ45 For data communication but only if a TCP IP module is inserted in the controller OEM MODBUS For data communication Terminal 56 screen Terminal 57 A Terminal 58 B Alternatively the terminals c...

Страница 3: ...ectly See separate literature No RC8AC Electric noise Cables for sensors DI inputs and data communication must be kept separate from other electric cables Use separate cable trays Keep a distance betw...

Страница 4: ...ion 6 20 AK SM Data communication Display EKA 163 164 L 15 m L 15 m Important All connections to the data communication MODBUS RS 485 and DANBUSS must comply with the requirements for data communicati...

Страница 5: ...arameter value is shown 4 Push the upper or the lower button and select the new value 5 Push the middle button again to set the value Cutout alarm relay receipt alarm see alarm code A short press of t...

Страница 6: ...Delay for temperature alarm after defrost A12 1 0 min 240 min 90 High alarm limit for thermostat 1 A13 1 50 C 50 C 8 Low alarm limit for thermostat 1 A14 1 50 C 50 C 30 High alarm limit for thermostat...

Страница 7: ...d changeover activate r21 8 alarm function when closed 9 alarm function when open 10 case cleaning pulse signal 12 night cover 15 appliance shutdown o02 1 0 15 0 Network address 0 off o03 1 0 240 0 On...

Страница 8: ...1 Temperature measured with S3 sensor u12 1 Status on night operation on or off 1 on u13 1 Temperature measured with S4 sensor u16 1 Thermostat temperature u17 1 Run time of thermostat cooling time in...

Страница 9: ...nations Settings from System manager AK SM Settings from AKM AKM destination Send via Network High 1 X Middle 2 X Low 3 X Log only Disabled Operating status Measure ment The controller goes through so...

Отзывы: