User Guide
|
Controller for appliance control, AK-CC 450
RS8EU702 | 29
© Danfoss | ADAP-KOOL® | 2015.10
Comp. off time when sensor fault
c87
1
0 min
240 min
30
Defrost
Defrost method
: 0=Off, 1= EL, 2= Gas, 3 = Brine
d01
1
1
1
1
1
1
1
1
1
0/Off
3/bri
1/EL
Defrost stop temperature
d02
1
1
1
1
1
1
1
1
1
0°C
50°C
6
Interval between defrost starts
d03
1
1
1
1
1
1
1
1
1
0 hrs/Off 240 hrs
8
Max. defrost duration
d04
1
1
1
1
1
1
1
1
1
0 min.
360 min.
45
Displacement of time on cutin of defrost at start-up
d05
1
1
1
1
1
1
1
1
1
0 min.
240 min.
0
Drip off time
d06
1
1
1
1
1
1
1
1
1
0 min.
60 min.
0
Delay for fan start after defrost
d07
1
1
1
1
1
1
1
1
1
0 min.
60 min.
0
Fan start temperature
d08
1
1
1
1
1
1
1
1
1
-50 °C
0 °C
-5
Fan cutin during defrost
0: stopped
1: Running
2: Running during pump down and defrost
d09
1
1
1
1
1
1
1
1
1
0
2
1
Defrost sensor:
0 =Stop on time, 1=S5, 2=S4, 3=
(Application 1-5 and 7: Both S5A and S6A.
Application 6 and 8: individual S5A and S5B)
d10
1
1
1
1
1
1
1
1
1
0
3
0
Pump down delay
d16
1
1
1
1
1
1
1
1
1
0 min.
60 min.
0
Drain delay (used at hot gas defrost only)
d17
1
0 min.
60 min.
0
Max. aggregate refrigeration time between two defrosts
d18
1
1
1
1
1
1
1
1
1
0 hrs
48 hrs
0/OFF
Heat in drip tray. Time from defrosting stops to heating in
the drip tray is switched off
d20
1
0 min.
240 min.
30
Delay time before opening hot gas valve
d23
1
0 min
60 min
0
Rail heat during defrost
0: off
1: on
2: Pulsing
d27
1
1
1
1
0
2
2
Defrost stop temp. thermostat band 2
d28
1
0°C
50°C
6
Max. defrost duration thermostat band 2
d29
1
0 min
360 min
45
Regulation parameter for refrigeration
Period time at PWM
n63
1
1
1
1
1
1
1
1
1
30 sec.
900 sec.
300
Max. opening degree at PWM
n64
1
1
1
1
1
1
1
1
1
0%
100%
100
Min. opening degree at PWM
n65
1
1
1
1
1
1
1
1
1
0%
90%
0
Expert setting. Windup at PWM
n66
1
1
1
1
1
1
1
1
1
0.2
1.0
1.0
Expert setting. Kp at PWM
n67
1
1
1
1
1
1
1
1
1
0.5
10.0
4.0
Expert setting. Tn at PWM
n68
1
1
1
1
1
1
1
1
1
60 sec
1800 sec
300
Fan
Fan stop temperature (S5)
F04
1
1
1
1
1
1
1
1
1
-50°C
50°C
50
Pulse operation on fans: 0=No pulse operation, 1=At
thermostat cuts out only, 2= Only at thermostat cut outs
during night operation
F05
1
1
1
1
1
1
1
1
1
0
2
0
Period time for fan pulsation (on-time + off-time)
F06
1
1
1
1
1
1
1
1
1
1 min.
30 min.
5
On-time in % of period time
F07
1
1
1
1
1
1
1
1
1
0 %
100 %
100
Real time clock
Six start times for defrost.
Setting of hours.
0=OFF
t01 -
t06
1
1
1
1
1
1
1
1
1
0 hrs
23 hrs
0
Six start times for defrost.
Setting of minutes.
0=OFF
t11 -
t16
1
1
1
1
1
1
1
1
1
0 min.
59 min.
0
Clock - Setting of hours
t07
1
1
1
1
1
1
1
1
1
0 hrs
23 hrs
0
Clock - Setting of minute
t08
1
1
1
1
1
1
1
1
1
0 min.
59 min.
0
Clock - Setting of date
t45
1
1
1
1
1
1
1
1
1
1 day
31 day
1
Clock - Setting of month
t46
1
1
1
1
1
1
1
1
1
1 mon.
12 mon.
1
Clock - Setting of year
t47
1
1
1
1
1
1
1
1
1
0 year
99 year
0
Miscellaneous
Delay of output signals after start-up
o01
1
1
1
1
1
1
1
1
1
0 sec
600 sec
5
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm
when open. 3=door alarm when open. 4=defrost start (pulse-
signal). 5=ext.main switch. 6=night operation 7=
Thermostat
band changeover
(activate r21). 8=alarm function when
closed. 9=alarm function when open. 10=case cleaning (pulse
signal). 11=forced cooling at hot gas defrost,
12=night cover.
15=application shutdown
o02
1
1
1
1
1
1
1
1
1
0
15
0
Continued
code
1 2 3
4
5 6 7
8
9
Min.
Max.
Fac.
Actual