Port locations and Gauge Installation
The following table and drawings show the port locations and gauge sizes needed. When testing system
pressures, calibrate pressure gauges frequently to ensure accuracy. Use snubbers to protect gauges.
Port Information
Port identifier
Port size
Wrench size
Reading
Gauge size, bar [psi]
L1, L2
1 1/16-12 UNF
9/16 internal hex
Case drain
10 bar [100 psi]
M1, M2
9/16-18 UNF
1/4 internal hex
System pressure
600 bar [10,000 psi]
M3, M4, M5
9/16-18 UNF
1/4 internal hex
Servo pressure
50 bar [1000 psi]
X1, M7
9/16-18 UNF
1/4 internal hex
Control pressure
50 bar [1000 psi]
Port Locations
M2
M1
Threshold
adjustment
M3
M5
M1
M5
M3
A
L2
L1
M7
P106 434E
M4
M4
X1
M7
X1
Radial ported motor
M3
M5
B
A
M4
System port A
M1+M2
System port B
Axial ported motor
Service Manual
Series 51 Hydraulic Proportional Controls Service Manual
Pressure measurements
10