Instruction
CF-RC Remote Controller
9. Troubleshooting
Error Indication
Possible Causes
Actuator/output (E03)
The output of Master Controller or the actuator connected
to this output is short-circuited or disconnected.
Low temperature (E05)
The room temperature is below 5°C. Try to verify the func-
tion of the room thermostat by carrying out a link test.
Link to Master Controller
(E12)
The room thermostat in the indicated room has lost the
wireless connection to Master Controller.
Low bat. in Room T. (E13) The battery level of the room Thermostat for the indicated
room is low, and the batte ries should be replaced.
Critical bat. in Room T.
(E14)
The battery level of the Room thermostat for the indicated
room is
critically
low. The batteries should be replaced as
soon as possible.
Link between MCs (E24)
The indicated Master Controllers have lost their wireless
connection.
The battery level of Remote Controller is low, and the bat-
teries should be replaced.