6.2. Connections
6.2.1. Mains connection
WARNING!
Potential risk of electric shock.
The device is a protective class 1 unit. A missing earth (ground)
contact may cause dangerous voltages in the housing and controls
and may lead to electric shock.
▪ Connect the unit to mains power supplies with protective earth
only.
▪ If there is any sign of obvious damage to the power cord
and/or mains connector, do not use the power cord and
replace it before further use.
▪ Please ensure the mains connector is accessible at any time to
disconnect the unit in case of malfunction or danger.
If the mains plug is not readily accessible due to mounting in a
19" rack or equipment cabinet, then the mains plug for the
entire rack or cabinet must be readily accessible.
▪ Do not connect or disconnect the powerCON
®
mains connector
under load or live.
Before connecting the device to mains voltage, check that the
mains voltage and frequency correspond to the specifications on
the rating label next to the mains connector socket on the rear
panel of the unit.
Mains voltage range:
100 to 240 V AC,
~
50/60 Hz, 1000 W.
A powerCON
®
mains connector socket
[1] is fitted on the rear
panel and an appropriate power cord
[2] is supplied.
Number of devices per phase conductor
When full output power is required, it is strongly recommended to
operate only
one device per phase conductor.
For further details please refer to
Þ
Chapter 14.4. "Current/
power draw and thermal dissipation" on page 79.
d&b 10D/30D Manual 1.10 en