1. The manufacturer bears responsibility for the greenhouse frame complete setup.
2. The manufacturer bears responsibility for the greenhouse
  assemblability in accordance with the manual.
3. The manufacturer bears responsibility for the greenhouse durability under specified 
magnitude of atmospheric actions.
4. Claim presentation period is 12 months from the date of purchase.

WARRANTY CONDITIONS

Warranty liabilities do not apply to cases of:
1. Greenhouse installation with violation of requirements of the manual.
2. Violation of the rules of operation.
3. Inappropriate use of the greenhouse.
4. Floods, hurricanes and other natural disasters.

 The manufacturer reserves the right for greenhouse engineering design changes.

WARRANTY LIABILITIES

RULES OF OPERATION

The greenhouse should be serviced in the winter period. The greenhouse has durability 

under  the  action  of  snow  loads  way  more  than  is  required  for  greenhouses,  but  less  for 
some snow areas in comparison with the general construction standards. According to SNIP 
2.10.04-85  «Greenhouses  and  seedbeds»  «weight  of  snow  blanket  on  1  m

2

  of  horizontal 

surface of the ground in design of static greenhouses…» should be taken from 10 to 40 kg/
m

2

 depending on a snow region. This is much less than the general construction standards for 

snow load, because it is assumed that on the current greenhouses a snowcap is not preserved 
until the next snowfall. According to the results of strength tests the limits of durability of the 
greenhouse frame are revealed: destroying snow load is 196 kg/m

2

, permissible load (with 

safety coefficient 1.4) – 140 kg/m

2

.

The permissible load approximately corresponds to the thickness of fresh snow 0.9 m and 

settled snow 0.45 m.  Thus, in operation it is necessary to prevent accumulation of snowcaps 
above specified limits.

If the greenhouse is not heated in winter, or it is supposed to use the greenhouse as an 

unheated housing, awning, warehouse, etc., it is necessary to control the snowcap (to shift 
the snow down with a wooden or plastic scraper, installed on a pole).  For these variants of 
operation it is possible to supply reinforced frames with a reduced interval between the power 
arcs under the snow load specified by the customer.

Do not allow damage to the frame, and if it happened, then hold timely repairs

It is not allowed to install the greenhouse without fastening on the ground because 

of the large sail area of the greenhouse and the possibility of floating away the 

unfastened greenhouse.

INTRODUCTION

Be careful during the assembly! Parts have sharp corners. Beware of cuts! The works 

shall be carried out in gloves.

1. General view of the frame is shown in Fig.1, with tambour - Fig.1a (tambour is to be 

purchased separately at the customer’s request). The frame is assembled from the shaped 

2. 

Indices:

м

 - small;

б

 - big;

к

 - end (of the greenhouse length); 

н

 - lower; 

ц

 - center;

д

 - door;

в

 - gates; 

п

 - right; 

л

 - left; 

П

 - band;

    - the arrow indicates the direction of

 the installation according to the diagrams in the instructions.

Some  parts  have  remaining 

free holes which is the result of 

the parts uniformity.

Do  not  violate  instructions!  Do 

not  install  the  bolts  and  nuts 

without  washers  -  this  may 

reduce  the  strength  of  the 

frame!

CLEANING AND WASHING OF THE POLYCARBONATE SHEETS.

1. Rinse the sheet with warm water.

2. Wash the sheet with a solution of mild soap or household detergent and warm water, 

using a soft cloth or sponge to remove dirt.

3. Rinse with cold water and dry with a soft rag to remove water.

Never  use  abrasives  or  highly  alkaline  cleaning  compositions  for  cleaning 

polycarbonate sheets. Dry rubbing of the surface will damage the protective 

layer  of  the  cladding  and  shorten  its  shelf  life.  Never  rub  the  surface  of 

polycarbonate sheets with brushes, metallic cloth or other abrasive materials.

when  disinfecting  the  greenhouse  from  pathogens  causing  fungal  and 

bacterial  diseases,  do  not  use  «sulfur  blocks»  to  avoid  frame  corrosion 

(blackening).

OPERATION RULES

INSTALLATION INSTRUCTIONS FOR THE «TITAN Arch 196» GREENHOUSE

Содержание TITAN Arch 196

Страница 1: ...17 02 2020 for Greenhouse TITAN Arch 196 Manual...

Страница 2: ...any length 1 2 f o e l p i t l u m min 4 2 m width 7 46 m height 3 8 m...

Страница 3: ...AGE TITAN Arch 196 2800 200 100 41 0 7 PACKAGE TITAN Arch 196 2800 200 100 34 0 8 PACKAGE TITAN Arch 196 500 300 100 14 0 9 PACKAGE TITAN Arch 196 2700 100 90 37 0 10 PACKAGE TITAN Arch 196 500 300 10...

Страница 4: ...TITAN Arch 196 5 Bottom arc strainer 2 2 73 5 Top arc strainer 2 2 73 6 Segment strainer 3 2 58 7 Radial strainer 1 4 0 3 7 Radial strainer 2 3 0 54 3 Support 2 0 29 1 Foundation stay brace 2 0 84 3 P...

Страница 5: ...78 Bolt 6 14 123 Bolt 6 20 50 Nut 6 251 Bracket 26 17 16 97 Hanger 3 Hinge 1 130 left 2 Straight lug 40 90 2 Pull 80 2 2 Self driving screw 97 Washer 6 91 Table 6 DETAILED PARTS LIST INSERT marking na...

Страница 6: ...e as an unheated housing awning warehouse etc it is necessary to control the snowcap to shift the snow down with a wooden or plastic scraper installed on a pole For these variants of operation it is p...

Страница 7: ...EXTENDING INSERTS 2 1 1 3 D 2 4 4 5 8 B D E C F Fig 1 General view of the greenhouse with two inserts total length is 8 4 m insert C 2 2 4 5 B 4 5 5 9 5 5 11 4 2 4 4 3 Vocabulary Left side on the lef...

Страница 8: ...WITH EXTENDING INSERTS ONE INSERT extends the greenhouse by 2 13 m Number of the inserts for the greenhouse is not limited Fig 1 Fig 1 General view with the anteroom ceiling window door wall side piec...

Страница 9: ...arts is carried out in a horizontal plane by connection on side walls of a shape Arcs are connected to each other by nesting at length of the cut with alignment of holes view A bolt 6 14 bolt 6 14 bol...

Страница 10: ...t 6 14 bolt 6 14 bolt 6 14 washer 6 washer 6 washer 6 washer 6 Foundation stay braces 1 supports 3 are connected 1 align the side flanges of shapes fig 1 7 view C R 9 10 9 9 9 1 10 10 10 10 10 10 10 1...

Страница 11: ...ly joined end runners 2 2 align the side flanges of shapes Runners deviate from the vertical under their own weight and abut against side walls of shapes of arcs 4 until the next operation Installatio...

Страница 12: ...washer 6 G 7 6 5 INSTALLATION SEQUENCE General view of the power arc General view of the power arc with the anteroom fig 3 5 fig 3 4 If thegreenhouseisequippedwiththeanteroom install details of the an...

Страница 13: ...st and middle runners first STAGE 4 fig 4 1 fig 4 2 2 2 fig 4 2 2 4 STAGE 5 End section installation Inthevariantofinstallation of the greenhouse without a foundation marking of axes is made on the gr...

Страница 14: ...and middle runners first using a stepladder Next power arc is joined to the power arc that has already been connected and so on all the arcs are alternatively joined It is recommended to connect the o...

Страница 15: ...eet After marking the sheet but prior to cutting it mark the side with the covering layer on each piece of the sheet when the shipping film is removed sheet sides look the same Shipping film shall be...

Страница 16: ...2 5 4 4 6 5 7 3 2100 730 1200 2400 2605 5210 2710 950 2500 12000 1100 wall ceiling window CUTTING LIST FOR THE ANTEROOM CUT POLYCARBONATE SHEET IN STRICT ADHERENCE TO FIG 10 3 Honeycomb polycarbonate...

Страница 17: ...fig 10 5 Fig 10 5 Using a knife adjust covering pieces to arcs 4 and girder 20 and then install sealing profile in accordance with fig 10 6 self tapping screw 4 2 2 Fig 10 4 end covering end covering...

Страница 18: ...from the base package washer 6 from the base package bolt 6 14 washer 6 nut 6 tingle arc base sheet At first install all joint plates and tingles 2940 3 0 0 0 2940 2100 nut 6 ridge shape washer 32 6 b...

Страница 19: ...rill holes in part 1 across the holes in bottom draw band top draw band top draw band bottom draw band nut 6 washer 6 bolt 6 60 washer 6 FASTENING OF COVERING bend the ends of the tingle top draw band...

Страница 20: ...0 germany dancover com Switzerland 0840 000125 schweiz dancover com France 0975 181 800 france dancover com Austria 0662 626935 austria dancover com Sweden 040 233 262 sverige dancover com Finland 0 9...