Section 4: Specifications
SS2000 D3 AND D6
11
4.5 C
URRENT
S
ETTINGS
The proper current setting for each motor is shown on the individual torque vs.
speed curves. Use this current level to obtain the torque shown. The access hole
for the switches which set the motor current level is located on the front of the
unit (see Figure 4.1). Select the desired operating current by setting the
appropriate switch to the "ON" position. Only one switch should be ON. If two
or more switches are ON, the one that selects the highest current level is the
active switch. The switch settings are:
Position
D3
Current
(amperes)
D6 Current
(amperes)
8
0.5
1.0
7
0.75
1.5
6
1.0
2.0
5
1.25
2.5
4
1.5
3.0
3
2.0
4.0
2
2.5
5.0
1
3.0
6.0
4.6 S
TEP
R
ESOLUTION
The number of pulses per revolution is selected using the rotary switch on the
front panel. The arrow on the switch knob can point to any of ten positions. The
following chart shows the number of pulses per revolution selected by each
switch position.
Switch
Position
Pulses Per
Revolution
1
200
2
400
3
1,000
4
2,000
5
3,200
6
7,200
7
10,000
8
20,000
9
25,000
0
50,000