Danaher Motion Superior Electric
Section 3: Installation Guidelines
SS2000 D3 AND D6
5
Figure 3.3 D6 Mounting Diagram
The unit should be mounted upright (with the cooling fins vertical) , or
proper cooling will not occur. Air flow should not be obstructed. Case
temperature should not 70° C (+158° F). Forced air cooling
may be required to maintain temperature within the stated limits.
When selecting a mounting location, it is important to leave at least two inches
(51mm) of space around the top, bottom and sides of the unit to allow proper
airflow for cooling.
It is also important to keep the drive away from obvious noise sources. If
possible, locate the drive in its own metal enclosure to shield it and its wiring
from electrical noise sources. If this cannot be done, keep the drive at least three
feet from any noise sources.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com