Unpacking and Inspecting  

SERVO

STAR

®

 

SP3 Power Block 

ELECTRICAL SPECIFICATIONS 

 

Product  Model 

CP303 

CP306 

CP310 

 

Voltage (Vac

L-L

) Nominal  

±

10% 

110-230 230 

 

115Vac  1

φ

 / 3

φ

 

1/3 

 

 

230Vac  1

φ

 / 3

φ

 

1/3 

3

φ

 only 

 

Line Frequency 

47-63 

 

KVA at 115 (1

φ

0.44 0.89 

 

 

Continuous Current (amps) at 115VAC 

3.9 

7.7 

 

 

Peak Current (amps) for 500 mSec 115VAC  

11.7 

23.1 

 

 

Peak Current (amps) for 2 Sec 115AC  

7.8 

15.4 

 

Main Input 

 

KVA at 230 (1

φ

0.89 1.8 

 

Power

 

Continuous Current (amps) at 230 (1

φ

3.9 7.7 

 

 

Peak Current (amps) for 500mSec at 230 (1

φ

11.7 23.1 

 

 

Peak Current (amps) for 2Sec at 230 (1

φ

7.8 15.4 

 

 

Line Fuses (FRN-R, LPN, or equivalent) 

10 

20 

 

 

KVA at 230 (3

φ

1.4 2.8  4.6 

 

Continuous Current (amps) at 230 (3

φ

3.5 7  12 

 

Peak Current (amps) for 500mSec at 230 (3

φ

10.5 21  36 

 

Peak Current (amps) for 2Sec at 230 (3

φ

7 14  24 

 

Line Fuses (FRN-R, LPN, or equivalent) 

10 

20 

25 

Logic Input 

+24VDC Ext. Logic Voltage (volts) 

22 - 27 

Power

 

+24VDC Ext. Logic Current (amps sink) 

0.5 

SoftStart 

Max. Surge Current (amps) 

30 

 

Max. Charge Time  (sec) 

0.25 

 

Fault Contact Rating 

1A 

 

Fault Contact Closing Period (mSec) 

Close = 3mS, Open = 2mS 

 

OverTemperature  trip (

°

C) 80

°

Protection 

UnderVoltage  Trip (nominal) 

90 VDC 

Functions 

OverVoltage Trip 

430 VDC 

 

OverTemperature Trip 

80

°

 

Internal heat dissipation (watts) 

60 

80 

132 

 

Continuous Power (KVA) at 115VAC 1

φ

    Line Input 

(45

°

 Ambient) 

0.35 0.7 

 

 

Continuous Power (KVA) at 230VAC 1

φ

    Line Input 

(45

°

C Ambient) 

0.7 1.4 

 

 

Continuous Power (KVA) at 230VAC 3

φ

    Line 

Input(45

°

 Ambient) 

1.1 2.2  3.5 

Main Output 

Continuous Current (Arms) 

10 

(Ma, Mb, Mc) 

Peak Current (Arms) for 500 mSec 

18 

20 

 

Peak Current (Arms) for 2 Sec 

12 

20 

 

PWM Frequency (kHz) 

15.5 

 

PWM Motor Current Ripple (kHz) 

31 

16 

16 

 

Form Factor (rms/avg) 

1.01 

 

Operation temperature 

5

°

C to 45

°

 

Storage temperature 

-0

°

C to 70

°

Environment 

Ambient humidity 

10% to 90% 

 

Atmosphere 

with no corrosive gasses or dust 

 

Altitude 

Derate 5% per 1000-ft (300m) above 

3300-ft (1000m) 

 

Vibration 0.5 

www.szcxi.com |  From

KOLLMORGEN

Содержание CP303

Страница 1: ...Danaher Motion SERVOSTAR SP3 Power Block Installation Manual KOLLMORGEN giving our customers freedom of design M SS 010 0104 www szcxi com From KOLLMORGEN...

Страница 2: ...e Kollmorgen Corporation Therefore information contained in this manual may be updated from time to time due to product improvements etc and may not conform in every respect to former issues Not for u...

Страница 3: ...d metal grounded surface Keep all covers and cabinet doors shut during operation Otherwise potential hazards could cause severe personal injury or damage to the product Be aware that during operation...

Страница 4: ...ves have been tested by an authorized testing laboratory in a defined configuration with the system components deSP3 Power Blockribed in this documentation Kollmorgen is not responsible for any diverg...

Страница 5: ...lated Cable Clamp 13 Alternative Bonding Methods 13 SYSTEM WIRING 15 MAIN POWER CONNECTOR 15 24V LOGIC POWER CONNECTOR OPTIONAL 16 STANDARD OPTION 17 Standard Option Block Diagram 18 INTEGRATED 8F OPT...

Страница 6: ...Kollmorgen Safety Instructions SERVOSTAR SP3 Power Block ii CURRENT SCALING 25 CUSTOMER SUPPORT 26 www szcxi com From KOLLMORGEN...

Страница 7: ...r additional details Metal to metal contact is important for electrical noise control 3 Wire the SP3 Power Block according to the System Wiring Diagram Pay particular attention to the pinout connector...

Страница 8: ...d option A Connect the cable C2 B Connect the 8F Delta Tau accessory 13 Configure the SP3 Power Block for your particular motor if this was not done at the factory 14 Tune the SP3 Power block for the...

Страница 9: ...rgen brushless motors and electronics are warranty for a period of 24 months from the time of installation or 30 months from time of shipment which ever comes first There are no other warranties expre...

Страница 10: ...servo amplifiers with the standards for industrial areas stated in the front of this manual only if Danaher Motion Kollmorgen delivers the components motors cables amplifiers etc PART NUMBER CP3 03 2...

Страница 11: ...volts 22 27 Power 24VDC Ext Logic Current amps sink 0 5 SoftStart Max Surge Current amps 30 Max Charge Time sec 0 25 Fault Contact Rating 1A Fault Contact Closing Period mSec Close 3mS Open 2mS OverTe...

Страница 12: ...Cx10 External Shunt Peak current amps 20 Regulator Minimum resistance 20 Watts 200 Capacitance Farads 0 00082 0 00164 Application BUS Voltage nominal VDC 325 Information VHYS Regen circuit turn off V...

Страница 13: ...2lb in 1 35Nm Hardware Motor Screw Size Torque Ground Screw Size Torque Control Logic AWG mm2 28 16 0 5 1 5 Motor Line AWG mm2 14 0 25 Main Input AWG mm2 14 25 12 4 Configurable I O wire gauge 22 18 A...

Страница 14: ...To ensure proper grounding and to optimize EMC the enclosure should have continuous ground continuity maintained between all metal panels This ground continuity is intended to be both a safety ground...

Страница 15: ...al ground The second is radiated high frequency emissions that are usually capacitively coupled from line to line and are differential in nature To properly mount the filters the enclosure should have...

Страница 16: ...The filtering of the lines feeding the motor provides additional attenuation of noise currents that may enter surrounding cables and equipment I O ports in close proximity Differential mode currents...

Страница 17: ...n Schaffner RD7137 36 0m5 A 96843 005 500 H 3 phase common mode choke 36 amps continuous Schaffner RD8137 64 0m5 A 96843 010 500 H 3 phase common mode choke 64 amps continuous I O Filtering I O filter...

Страница 18: ...d This high frequency ground is made with the use of a flat braid or copper bus bar Do not use a standard wire for the high frequency ground When connecting high frequency grounds use the shortest bra...

Страница 19: ...lide onto the bus bar The cable with exposed shield is inserted through the SK piece and the thumbscrew on top of the SK piece is used to tighten the connection between the cable shield and the bus ba...

Страница 20: ...Power Block 14 copper bus bar cable shield compressed on copper bus bar Thumb screw to tighten down shield to bus bar SK 8 14 20 Shielded terminal block Phoenix Contact Side View Phoenix Contact Top V...

Страница 21: ...SERVOSTAR SP3 Power Block has two options the Standard Option and the Integrated 8F Option The Integrated 8F Option includes the interface features of the Delta Tau Data Systems Inc s Accessory 8F di...

Страница 22: ...B L3 L2 L1 THE SERVOSTAR SP3 OPERATES WITH VOLTAGES AS HIGH AS 230 VAC USE CAUTION REFER INSTALLATION AND TROUBLESHOOTING TO QUALIFIED PERSONNEL ONLY WARNING HIGH VOLTAGE MAY EXIST UP TO 5 MINUTES AFT...

Страница 23: ...WMABOT Command Phase A bottom command 11 PWMBTOP Command Phase B top command 12 PWMBBOT Command Phase B bottom command 13 PWMCTOP Command Phase C top command 14 PWMCBOT Command Phase C bottom command...

Страница 24: ...s option has four connectors C1 to C4 on the front panel and one connector C5 on the top of the unit The PMAC2 has up to 4 machine interface connectors labeled JMACH1 through JMACH4 Each JMACH connect...

Страница 25: ...bles can refer to Appendix A for drive motor pinout connections Connector C1 Hall Effect Device Feedback Connector C1 interfaces between the SP3 and the Hall Effect Devices HED on the motor These sign...

Страница 26: ...Return PMAC_GND 8 EV5 Return E5V Return PMAC_GND 9 Hall 1 Hall 1 H1 10 Hall 2 Hall 2 H2 11 Hall 3 Hall 3 H3 12 Shield Shield SHIELD 13 Thermostat High Thermostat High MOTOR THERMp 14 Shield Shield SH...

Страница 27: ...22 B11 NC Not Connected 23 A12 ACLK Input A D Converter Clock 24 B12 ACLK Input A D Converter Clock 25 A13 ASTB Input A D Converter Strobe 26 B13 ASTB Input A D Converter Strobe 27 A14 ADAA Output Ch...

Страница 28: ...below Connector C5 User Flags PIN SYMBOL FUNCTION DESCRIPTION 1 USER Input General Capture Flag 2 PLIM Input Positive Limit Flag 3 MLIM Input Negative Limit Flag 4 HOME Input Home Flag 5 FL_RT Input R...

Страница 29: ...mplifier over current F 1100 PWM fault frequency A1 1010 12V under voltage A2 1010 12V under voltage A3 1010 5V under voltage A4 1010 Reference under voltage The following provides a description of so...

Страница 30: ...on t1 1011 Over current shut down t2 1011 Motor over temperature t3 1011 Power amplifier over temperature o 1101 Power amplifier over voltage u 1110 Power amplifier under voltage Watch dog P1 1001 Dri...

Страница 31: ...Enabled factory default Open Closed Enabled Closed Open Enabled CURRENT SCALING The SP3 measures the current of the drive and makes the value available to the user via a 10 volt signal The currents me...

Страница 32: ...ive way contact your local sales representative for order status and delivery information product information and literature and application and field technical assistance If you are unaware of your l...

Отзывы: