Location Value
Description
7
Line sum (23…16)
8
Line sum (31…24)
9
Line sum (39…32)
10
Pixels above threshold (7…0)
Monitor these valu es (either above or
below threshold ) and ad ju st cam era
d igital gain and backgrou nd su btract to
m axim ize scene contrast. This p rovid es a
basis for au tom atic gain control (AGC)
11
Pixels above threshold
(15…8)
12
Pixels above threshold
(23…16)
13
Pixels below threshold (7…0)
14
Pixels below threshold (15…8)
15
Pixels below threshold
(23…16)
16
Differential line su m (7..0)
Use these valu es to focu s the cam era.
Generally, the greater the su m the greater
the im age contrast and better the focu s.
17
Differential line su m (15…8)
18
Differential line sum (23…16)
19
Differential line sum (31…24)
20
Differential line sum (39…32)
Setting Thresholds
Setting an Upper Threshold
Pu rp ose:
Sets the u p p er threshold lim it to rep ort in the end -of-line
sequ ence.
Syntax:
sut
i
Syntax Elem ents:
i
Up p er threshold lim it in range from
0
to
4095
.
N otes:
LVAL is not high d u ring the end -of-line statistics.
Related Com m and s:
els
,
slt
Exam p le:
sut 1024
All manuals and user guides at all-guides.com
Содержание Piranha HS Series
Страница 84: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 84 All manuals and user guides at all guides com ...
Страница 108: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 108 All manuals and user guides at all guides com ...
Страница 110: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 110 All manuals and user guides at all guides com ...
Страница 120: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 120 All manuals and user guides at all guides com ...