4.2 Selecting the Number of CCD Integration Stages
Pu rp ose:
In TDI Mod e, this com m and ad ju sts the sensitivity level in you r
cam era by setting the nu m ber of CCD integration stages. In Area
Mod e, the vertical height of the im age sensor is controlled by the
nu m ber of stages.
Syntax:
stg
m
Syntax Elem ents:
m
N u m ber of stages to u se. Available valu es (not inclu d ing the
H S-82 m od el) are
16
,
32
,
48
,
64
,
80
, and
96
. Factory setting is
96
.
Available valu es for the H S-82 m od el are
8
,
16
,
24
,
32
,
40
, and
48
(d efau lt).
Exam p le
stg 64
A note on stage selection (stg) and the HS-82 model of camera:
The sensitivity level of a cam era can be ad ju sted by setting the nu m ber of CCD
integration stages. For su ch p u rp ose, the stand ard H S-80-08K80-00-R cam era has six
d ifferent allow able settings: 16, 32, 48, 64, 80 and 96. With m od ifications to the binning
setu p , the H S-82-04k80-00-R cam era retains this featu re of the stand ard cam era, bu t the
nu m ber of stages is halved (8, 16, 24, 32, 40 and 48) to reflect this change.
All manuals and user guides at all-guides.com
all-guides.com
Содержание Piranha HS Series
Страница 84: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 84 All manuals and user guides at all guides com ...
Страница 108: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 108 All manuals and user guides at all guides com ...
Страница 110: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 110 All manuals and user guides at all guides com ...
Страница 120: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 120 All manuals and user guides at all guides com ...