Piranha HN RoHS User Manual
Teledyne DALSA
03-032-20135-00
59
Mnemonic
Syntax Parameters
Description
set subtract background
ssb
i
Subtract the input value from the output signal.
i
= Subtracted value in a range from
0
to 4096.
set sync frequency
ssf
f
Set the frame rate to a value from:
TDI:
1
-
34246
Area:
1-130
Value rounded up/down as required.
set system gain
ssg
i
Set the digital gain.
i
= System gain in a range from
0
to
61438
. The digital
video values are multiplied by this number.
set set number
ssn
i
Sets the “set” number from where these values are
loaded and saved.
i
= set number in a range from 0 to 4.
stage select
stg
i
Sets the number of stages.
Allowable values are:
16,64, 128, 192, 240, 256
set video mode
svm
i
Switch between normal video mode and test patterns:
0 (video) to 4 (test patterns).
set TDI mode
tdi
i
Set the camera’s operating mode.
0
: Area Mode
1
: TDI Mode
Refer to
Setting a Region of Interest
for details
update gain reference
ugr
Changes 0dB gain to equal the current gain value
verify temperature
vt
Check the internal temperature of the camera
verify voltage
vv
Check the camera’s input voltages and return OK or fail
write FPN coefficients
wfc
Write all current FPN coefficients to EEROM.
write PRNU coeffs
wpc
Write all current PRNU coefficients to EEROM.
write user settings
wus
Write all of the user settings to EEROM.