Piranha ES-Sx User Manual
03-032-20162-00
Teledyne DALSA
50
Appendix A
Error Handling and
Command List
A1 Error Handling
The following table lists warning and error messages and provides a description and
possible cause. Warning messages are returned when the camera cannot meet the full
value of the request; error messages are returned when the camera is unable to complete
the request.
Table 8: Warning and Error Messages
Warning Messages
Camera Response
Comment
OK>
Camera executed command
Warning 01: Outside of specification>
Parameter accepted was outside of specified
operating range (e.g. gain greater than ±10 dB of
factory setting, or SSF below specification).
Warning 02: Clipped to min>
Parameter was clipped to the current operating
range. Use GCP or GET to see value used.
Warning 03: Clipped to max>
Parameter was clipped to the current operating
range. Use GCP or GET to see value used.
Warning 04: Related parameters
adjusted>
Internal operating condition is adjusted to
accommodate the entered command. E.g.
requesting exposure time longer than line time
automatically adjusts the line time to meet the
exposure time requirement.
Warning 07: Coefficient may be
inaccurate A/D clipping has occurred>
In the region of interest (ROI) greater than 6.251%
single or 1% of averaged pixel values were zero or
saturated.
Warning 08: Greater than 1% of
coefficients have been clipped
Greater than 1% of FPN or PRNU coefficients have
been calculated to be greater than the maximum
allowable and so were clipped.
Warning 09: Internal line rate inconsistent
with read out time>
Changing this parameter has changed read out
time and that is greater than the
internal
SYNC