Piranha ES-Sx User Manual
Teledyne DALSA
03-032-20162-00
15
Table 6: Camera Control Configuration
Signal
Configuration
CC1
EXSYNC
CC3
Forward
The camera ships in internal sync, internal programmed integration (exposure mode 7) TDI Mode.
EXSYNC (Triggers Frame Readout)
Frame rate can be set internally using the serial interface. The external control signal
EXSYNC is optional and enabled through the serial interface. This camera uses the
falling
edge of EXSYNC
to trigger pixel readout. Section
Exposure Mode and Line/Frame Rate
for details on how to set frame times, exposure times, and camera modes.
Direction Control
You control the CCD shift direction through the serial interface. With the software
command,
scd
, you determine whether the direction control is set via software control or
via the control signal on CC3. Refer to section
Setting the Camera’s CCD Shift Direction
for details.
Output Signals
Note that LVAL and FVAL are embedded in data lanes. For additional information refer
to the HSLink supplementary information below.
Rx
Tx
5 serial lanes
@ 312.5 Mb/sec
Camera
Frame Grabber
IMPORTANT:
This camera’s data
should be sampled on
the rising edge of
STROBE.
i