27
Piranha 2 User’s Manual
03-032-00493-14
Teledyne DALSA
3.8 Setting the Video Mode
The vid eo m od e sets w hether the cam era is ru nning in calibrated or u ncalibrated m od e,
or if it is generating a test p attern.
To set the vid eo m od e, u se the com m and :
Syntax:
svm
i
Syntax Elem ents:
i
Vid eo m od e to u se. Allow able valu es are:
0
Uncalibrated vid eo, d eactivated vid eo correction
1
Calibrated vid eo, activated vid eo correction
2
Test p attern right
N otes:
To obtain the cu rrent vid eo m od e, u se the com m and
gcp
.
3.9 Setting Line Rate and Exposure Mode
The camera’s line rate (synchronization) is generated internally or input from a frame
grabber/ host system . With six d ifferent exp osu re m od e settings, the Piranha 2 d elivers
m any p ossibilities for flexible cam era tim ing. Table 9 ou tlines each of these six exp osu re
modes, and is followed by a full explanation on how to set the camera’s frame rate and
exp osu re tim e.
Table 9: Piranha 2 Exposure Modes
Programmable Line Rate Programmable Exposure Time
Mode SYNC
PRIN
Description
1
Internal
Internal
N o
N o
Maxim u m line rate and exp osu re tim e
(factory setting)
2
Internal
Internal
Yes
Yes
Exp osu re control OFF u ntil a set
com m and is sent
3
External
Internal
N o
N o
Maxim u m exp osu re tim e
4
External
Internal
N o
N o
Sm art EXSYN C
5
External
External
N o
N o
6
External
Internal
N o
Yes
Fixed integration tim e
To obtain the cu rrent valu e of the exp osu re m od e, u se the com m and
gcp
.
When setting the cam era to external sign al m od es, EXSYN C and / or PRIN m u st be
su p p lied .
Overview: Setting Line Rate and Exposure Time
The camera’s line rate (synchronization) can be generated internally through softw are
com m and s or in p u t externally from a fram e grabber/ h ost system . To select how you
want the camera’s line rate to be generated:
1.
You m u st first set the cam era m od e u sing the
sem
com m and . Refer to Setting the
Exp osu re Mod e on the follow ing p age for d etails.
2.
Then, w hen ap p licable, u se the com m and s
ssf
(m od e 2 only) to set the line rate
and / or
set
(m od e 2 or 6), to set the exp osu re tim e. Refer to Setting Line Rate and
Setting Exp osu re Tim e below for d etails.
All manuals and user guides at all-guides.com
Содержание Piranha 2 Series
Страница 42: ...42 Piranha 2 User s Manual 03 032 00493 14 Teledyne DALSA All manuals and user guides at all guides com...
Страница 50: ...50 Piranha 2 User s Manual 03 032 00493 14 Teledyne DALSA All manuals and user guides at all guides com...
Страница 58: ...58 Piranha 2 User s Manual 03 032 00493 14 Teledyne DALSA All manuals and user guides at all guides com...
Страница 62: ...62 Piranha 2 User s Manual 03 032 00493 14 Teledyne DALSA All manuals and user guides at all guides com...
Страница 78: ...78 Piranha 2 User s Manual 03 032 00493 14 Teledyne DALSA All manuals and user guides at all guides com...
Страница 84: ...84 Piranha 2 User s Manual 03 032 00493 14 Teledyne DALSA All manuals and user guides at all guides com...