78
Operational Reference
Genie Monochrome Series-GigE Vision Camera
ImageTimeout
RW
N.conn
EXP10: 6
700000
min=10000, max=6000000,
inc=1
LUTData
RW
N.conn
(type Buffer)
FlatFieldGainBuffer
RW
N.conn
(type Buffer)
FlatFieldOffsetBuffer
RW
N.conn
(type Buffer)
UserBuffer
(see
Accessing the Genie User Buffer)
RW
N.acq
(memory of type Buffer
available to the user)
FlatFieldGainMin
RO
N.conn
EXP10: 0
(see note
1)
min=0, max=16777215, inc=1
FlatFieldGainMax RO
N.conn
EXP10:
0
(see note
1)
min=0, max=16777215, inc=1
FlatFieldOffsetMin RO
N.conn
EXP10:
0
(see note
1)
min=0, max=16777215, inc=1
FlatFieldOffsetMax
RO
N.conn
EXP10: 0
(see note
1)
min=0, max=16777215, inc=1
FlatFieldWidth
RO
N.conn
EXP10: 0
(see note
1)
min=0, max=16777215, inc=1
FlatFieldHeight RO
N.conn
EXP10:
0
(see note
1)
min=0, max=16777215, inc=1
InputPinStatusInput_1 RO
Invalid
EXP10:
0
1
min=0, max=1, inc=1
InputPinStatusInput_2 RO
Invalid
EXP10:
0
1
min=0, max=1, inc=1
Note 1: not displayed in CamExpert; not saved in a camera configuration file (CCF)
Feature Type BOOL
Feature Name
Access
W-mode
Type
Value
Notes
LUTEnable RW
N.conn
BOOL
True/False
TriggerEnable RW
N.acq
BOOL
True/False
TriggerSoftware
RW
Always
BOOL
True/False
AcquisitionArm
WO
N.acq
BOOL
True/False
(see note 2)
FlatFieldEnable
RW
N.conn
BOOL
True/False
FlatFieldCalibrationEnable
RW
N.conn
BOOL
True/False
(see note 3)
TimestampReset
WO
Always
BOOL
True/False
SaveCameraConfiguration WO
N.conn BOOL
True/False
LoadCameraConfiguration
WO
N.conn
BOOL
True/False
Note 2: Prepares the Genie for an optimal acquisition start with minimal delay. This feature should be set true only
after all other features are set else the effect of AcquisitionArm is canceled.
Note 3: FlatFieldCalibrationEnable is set True before a calibration sequence is performed. When calibration is
enabled features such as Crop, Flip, LUT, etc. are reset to their default state before the calibration sequence is
started. The application would need to restore these features after flat field calibration is complete.