![Dalsa Genie M640 Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/dalsa/genie-m640/genie-m640_user-manual_3484186107.webp)
Genie Monochrome Series-GigE Vision Camera
Technical Specifications
105
External Outputs
Programmable output mode such as strobe, event notification, etc. (see
"
Output Control via Sapera LT or
GigE Vision Compliant Applications
" on page 60
).
Genie
NEC
PS2805-1
680
5V
10K
75
Example 74LS14
Output Signal
Hirose 12
connector
Output Driving a TTL User Circuit
The opto-coupler is typically a NEC PS2805-1 with the following characteristics.
Output Electrical Parameter Description
Value
Maximum voltage difference
13 V
Maximum current through opto-coupler
12mA
Minimum output pulse width
100 us
Maximum switch closure transition time
12 µs
Maximum switch open transition time
40 µs