Display Troubleshooting
17
To put the PLR into self-test mode, loop a SATA cable between ports A and B. Then take a
fiber cable and connect the fiber ports together. Once the cables are connected, cycle
power to the PLR and it will boot-up in self-test mode. Following is a table of a few
possible messages. Contact Daktronics Technical Support for additional information or
questions.
If any Err message is displayed, send the PLR back to Daktronics for repair or
replacement.
Code
Description
8
8
8
Testing 7 segments (held for 2 seconds)
t
s
t
Initial test in progress (60-second
duration)
P
A
S
All tests passed
E
r
r
Test failures reported
F
0
1
Fiber Port A Error
F
0
2
Fiber Port B Error
F
0
3
RJ45 IN (Port A) Error
F
0
4
RJ45 OUT (Port B) Error
F
0
5
ProLink5 (SATA) Port A Error
F
0
6
ProLink5 (SATA) Port B Error
C
N
P
CAN Light Sensor (J8) Port Pass
C
N
F
CAN Light Sensor (J8) Port Fail
Содержание VANGUARD VC6