Electrical Installation

4

4  Electrical Installation

This section explains the steps necessary to make final electrical connections to the 

display from the primary power source. For display-specific power requirements, refer to 

the 

Shop Drawing

 or label on the rear of the display. Follow all installation guidelines.

Warnings and Disclaimers 

•  Ensure that all electrical work meets or exceeds all local or national electrical codes. 
•  Provide the required power to the display as listed on the product labels, 

specifications, or site-specific riser drawings. The conductor size may vary based on 

the length of the power run. 

•  Consider implementing a separate circuit for the display using an isolation 

transformer or dedicated transformer. 

• 

Daktronics assumes no liability for any issues caused by line voltage fluctuations or 

other improper power conditions.

Important Notes

• 

Qualified personnel must perform electrical installations to prevent injury to personnel 

and damage to the equipment.

•  Daktronics engineering staff must approve any changes made to the display. Before 

altering the display, submit detailed drawings for the proposed modifications to the 

Daktronics engineering staff for evaluation and approval, or the warranty will be void.

•  Improper installation could result in serious damage to the equipment and could be 

hazardous to personnel.

•  Size conductors of circuits that deliver power to the display according to national 

and local electrical codes so the power distribution system delivers full-load power to 

the display while maintaining a voltage within 5% of the utility nominal voltage. 

Power Requirements

•  Install the display according to all applicable local and national electrical codes. This 

includes proper grounding and bonding of the display.

•  Do not connect the display to any voltage other than that listed on the Daktronics 

product label.

•  Displays use single-phase power. Proper power installation is imperative for display 

operation. 

Main Disconnect

Daktronics requires using a power disconnect switch with the display. A disconnect allows 

all ungrounded conductors to be disconnected near the point of power connection.
Locate the disconnecting means either in a direct line of sight from the display or so it 

can be locked in the open position. This ensures that power is not reconnected while 

service personnel work on the display.

Содержание Large Matrix Galaxy GT6X Series

Страница 1: ...201 Daktronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 SMALL MATRIX GALAXY GT6X SERIES INSTALLATION AND OPERATION MANUAL P2056 DD4302532 Rev 04 22 April 2022...

Страница 2: ...limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a com...

Страница 3: ...oftware Configuration 12 First Time Venus Login 12 Logging In Daktronics Web Hosted Server 12 Logging In Customer Local Hosted Server 12 Venus Menu Overview 13 Venus System Setup 13 Contact Informatio...

Страница 4: ...This page intentionally left blank...

Страница 5: ...trol system Refer to Daktronics Warranty and Limitation of Liability p 29 at the end of this manual for the full Daktronics Warranty and Limitation of Liability Contact Information For assistance befo...

Страница 6: ...power is available at sign structure refer to Shop Drawing for display power requirements Ensure the display cabinet has no holes accidental or intentional that will allow water to enter the display...

Страница 7: ...awing Use all lift eyes when lifting the display Do not open the DMP enclosure Do not drill holes into the display unless noted Do not block display ventilation system Do not use the lift eyes for dis...

Страница 8: ...he display submit detailed drawings for the proposed modifications to the Daktronics engineering staff for evaluation and approval or the warranty will be void Improper installation could result in se...

Страница 9: ...conduit following local code specifications 3 Terminate display power either to the J box or internally at the power termination panel 4 Connect the grounding conductor to the grounding lug on the re...

Страница 10: ...d to the J box on displays However larger displays require power to be terminated internally in the Power Termination Panel Displays With an External Power Termination J box To terminate hot neutral a...

Страница 11: ...E LOAD Z3 Top Z4 Bottom LINE LOAD Four Breaker Connections White Neutral Wiring Z1 Load to Pin 1 of J41 White Neutral Wiring Z2 Load to Pin 1 of J42 White Neutral Wiring Z3 Load to Pin 1 of J43 White...

Страница 12: ...onnect the signal between the two faces Refer to options 1 and 2 below for your specific application Option 1 Connect a cable from the Signal Out jack on primary face to Signal In jack on mirror face...

Страница 13: ...n Boot Sequence The information in the boot sequence includes the following Start Up Checklist Confirm power is correctly connected to the display Confirm there is sufficient power according to displa...

Страница 14: ...and eliminating manual configuration of the player When the display is connected to a network that supports DHCP a default DHCP name similar to DMP8 xx xxxx or DMP5 xx xxxx where xxxx represents a un...

Страница 15: ...is listed below with its manual number These are the standard communication types but each site is unique and may include additional equipment If problems arise contact the display s service company...

Страница 16: ...required only for the first time login to VCS 4 Update the account information fields in the User Information and Additional Information sections and click Save Logging In Customer Local Hosted Serve...

Страница 17: ...tisers Users Lists current user profiles and allows users to update passwords or add new users Displays Lists all available displays and provides basic management tools including Devices for linking D...

Страница 18: ...under the user name to open the contact information window Refer to Figure 13 If further assistance is required Daktronics Customer Service is available 7 a m to 7 p m CST Monday to Friday via telepho...

Страница 19: ...lay Access 1 Disconnect power to the display 2 Remove the bottom two modules from the second column on the left side of the display with a 1 8 hex head wrench A component layout is shown in Figure 14...

Страница 20: ...wing for ventilation requirements Fans help bring fresh air into the display while exhausting hot air through the upper vents Fans are controlled via a thermostat in the display cabinet The thermostat...

Страница 21: ...dry soft terry cloth towel horizontally across each row of LEDs Make four passes per row of LEDs before moving to the next row of LEDs Work from top to bottom safely within reach from a lift or a stag...

Страница 22: ...ws an example of how power is routed through the display 1 AC Power enters the display through the J box on the rear of the display 1 2 Power then travels to the Power Termination Panel 2 3 Power is d...

Страница 23: ...A on the first Module 3a and travels from module to module via SATA cables 3b Refer to Figure 20 Signal returns to the Controller SATA B jack 3c 4 In 2V displays signal from the primary display face...

Страница 24: ...ment display To put the PLR into self test mode loop a SATA cable between ports A and B Then take a fiber cable and connect the fiber ports together Refer to Figure 22 Once the cables are connected cy...

Страница 25: ...conds Module Self Test If a module is blank but has power supplied to it perform a module self test to diagnose a module or signal cable failure To perform a self test follow these steps 1 Attach a si...

Страница 26: ...isconnect the power cable 5 Carefully disconnect the two signal cables from the module 6 Connect the two signal cables to the new module 7 Connect the power cable 8 Insert the tabs at the bottom of th...

Страница 27: ...nt of the controller Note Do not allow the modules to hang by their cables 2 Disconnect the cables from the controller 3 Loosen the screw securing the controller enclosure and bracket 4 Carefully lift...

Страница 28: ...received mail the old part to Daktronics If the replacement part fixes the problem send in the problem part which is being replaced a Package the old part in the same shipping materials in which the r...

Страница 29: ...tem carefully to prevent damage during shipment Electronic components such as printed circuit boards should be placed in an antistatic bag before boxing 4 Enclose Your name Address Phone number The RM...

Страница 30: ...This page intentionally left blank...

Страница 31: ...ock Diagram GT6X DMP 3PLR 6 Mods Tall DWG 4285175 Block Diagram GT6X DMP 4PLR DWG 4285176 Block Diagram GT6X DMP 5PLR DWG 4285177 Block Diagram GT6X DMP 6PLR DWG 4285178 Block Diagram GT6X DMP ONE MOD...

Страница 32: ...Daktronics Warranty and Limitation of Liability 28...

Страница 33: ...Daktronics Warranty and Limitation of Liability 29 B Daktronics Warranty and Limitation of Liability This section includes the Daktronics Warranty Limitation of Liability statement SL 02374...

Отзывы: