background image

DAKTRONICS AQUATICS MAINTENANCE CHECKLIST 

 

DD3691471  072017 

201 Daktronics Drive  PO Box 5128  Brookings, SD 57006-5128 

 

800-325-8766  605-692-0200  fax 605-697-4700 

www.daktronics.com  email [email protected] 

 

If this take a long time to recharge, clean the terminals of 

the touchpad cable and test again. 

 

Tip: Plug touchpad cable directly into the voltmeter or use 

an additional dual banana to test while plugged into the 

deck connection. 

 

 

 

Relay Take-off 

Platform 

o

 

Visually inspect the sides, back and front for cracks and/or breaks. 

o

 

Visually inspect the gray electronics box for cracks. 

o

 

Visually inspect the cable strain reliefs, ensuring they are secure and not 

broken, loose, or missing. 

o

 

Visually inspect the RTOP cart for any damage. 

o

 

Testing: 

1.

 

Ensure a new battery (if possible) is installed in the electronics box.

 

2.

 

Verify the red LED on the electronics box is flashing.  

*The RTOP must be plugged into the lane harness and the OmniSport 

connected and setup in Swimming mode.

 

3.

 

Place your hand flat on the RTOP and hold for two seconds.

 

4.

 

Remove you hand quickly, and the red LED will turn solid for ~1 

second then return back to a flashing/ready state.

 

5.

 

The RTOP time should also be able to be captured on the OmniSport 

printout as long as settings/event are configured correctly. 

 

 

Relay Take-off Platform (RTOP) Manual

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pro Swimming 

 

 

 

 

 

 

 

 

 

 

 

 

o

 

Verify software is up to date. *Verify version entitlement; Contact Daktronics 

Help Desk if questions arise. 

o

 

Verify software opens correctly without errors.  

o

 

If customer has an Ethernet OmniSport it can communicate via network, or 

connect (USB/Serial adapter) to Pro Swim laptop and install driver (if 

needed). 

o

 

Connect standard Ethernet cable from Pro Swim laptop directly to Ethernet 

Omni or a network router/switch. 

o

 

If serial, connect cable from J4 EXPANSION PORT on the OmniSport 2000 

to the serial cable/adapter on the Pro Swim computer. 

o

 

Verify communication between devices. *May need to change com port 

value in Pro Swim, or set to UDP. 

Detailed Instructions: ED-13876

 

 
 
 
 
 
 
 
 
 
 
 
 

 

   

 

 

 

 

 

 

 

 

 

 

 

Содержание Aquatics

Страница 1: ... o Verify that thermal paper is installed in printer location and feeds prints correctly o Power up OmniSport console to verify firmware is up to date update if needed Must be newer than 8 3 27 to update in the field o Perform Mock swim race after completing checklist to verify all inputs and outputs are working including scoreboard RTD data OmniSport 2000 Manual ED 13312 On deck Equipment lane mo...

Страница 2: ...hes knobs cabling and connections o Testing 1 Test for charger functionality by connecting to the HS 200 Charging LED should light when plugged in 2 Ensure microphone is connected to the horn start assembly Wireless models ensure belt pack has a new battery and matches the wireless channel set on the HS 200 base assembly and has the antenna mounted on the base unit 3 Set volume controls to desired...

Страница 3: ...and when pressing on the pad it should create a shorted connection 4 If the pad passes the try test it can be put in the water to complete the we test by measuring for DC voltage Wet Test 1 1 Place all touchpads into the water and connect to their lane connections 2 Turn on the OmniSport 2000 and go into swimming mode 3 Press MENU 5 2 and go into the test mode 4 Use your hand or a swimmer to tap t...

Страница 4: ...nto the lane harness and the OmniSport connected and setup in Swimming mode 3 Place your hand flat on the RTOP and hold for two seconds 4 Remove you hand quickly and the red LED will turn solid for 1 second then return back to a flashing ready state 5 The RTOP time should also be able to be captured on the OmniSport printout as long as settings event are configured correctly Relay Take off Platfor...

Страница 5: ...al cable adapter on the Pro Dive computer o Verify communication between devices May need to change com port value in Pro Dive or set to UDP o Tip When using serial connections with an Ethernet OmniSport the network port must be disabled to allow serial communications MENU 4 7 7 NETWORK PRO OFF will allow you to shut off the Network Pro option Detailed Instructions ED 16444 Hy Tek Meet Manager o V...

Страница 6: ...setups use Generic Serial for Alternative configurations CTS Timer o Verify judge console firmware is up to date 3 0 or higher JC 100 and RC 100 options o Verify base station firmware is up to date if using wireless judge consoles 3 0 or higher o Verify the base station function Function setting should be set to a 6 on version 3 0 and higher Function 1 for earlier versions o Verify the correct 900...

Отзывы: