DAKTRONICS AQUATICS MAINTENANCE CHECKLIST 

 

DD3691471  072017 

201 Daktronics Drive  PO Box 5128  Brookings, SD 57006-5128 

 

800-325-8766  605-692-0200  fax 605-697-4700 

www.daktronics.com  email [email protected] 

o

 

Testing: 

1.

 

Verify deck plate connections are received into the  

OmniSport 2000. 

2.

 

Connect the OmniSport 2000 and all cabling to the proper wall plate 

in order to receive touchpad and button data. 

3.

 

Turn on the OmniSport 2000 and enter swimming mode. 

4.

 

The OmniSport should show 

( - ) 

marks across the LCD for the proper 

number of lanes.

 

5.

 

Press 

MENU > 5 > 2

 to go into the testing mode.

 

6.

 

Test each deck plate by placing a push button into each 

touchpad/button connection and pressing the button. 

TP, B1, B2, B3

 

will display on the OmniSport 2000 LCD if working correctly. 

 

 

 

 

Horn Start

 

o

 

Visually inspect horn start and microphone. (indicators, switches, knobs, 

cabling, and connections). 

o

 

Testing: 

1.

 

Test for charger functionality by connecting to the  

HS-200. Charging LED should light when plugged in.

 

2.

 

Ensure microphone is connected to the horn start assembly. Wireless 

models, ensure belt pack has a new battery, and matches the wireless 

channel set on the HS-200 base assembly, and has the antenna 

mounted on the base unit.

 

3.

 

Set volume controls to desired levels (not min or max) and power up 

the HS-200 unit.

 

4.

 

When the 

ON-READY LED 

is on, press the PUSH TO TALK lever 

while speaking to ensure audible, then while holding this press small 

button on top of the mic at the same time. This will trigger a tone and 

a strobe from the HS-200 assembly, while starting the clock on the 

OmniSport.

 

 

A dual banana (start cable) will need to be ran between 

the HS-200 and the OmniSport start circuit to initiate the 

start. *OmniSport 2000 Start Input settings much match 

connection at the HS-200 (N.O. vs. N.C.). 

 

Lane and/or Aux speakers must be connected to test 

each remote speaker/location. 

 

HS-200 Manual=ED-12935

 

 

          

 

 

 

Содержание Aquatics

Страница 1: ... o Verify that thermal paper is installed in printer location and feeds prints correctly o Power up OmniSport console to verify firmware is up to date update if needed Must be newer than 8 3 27 to update in the field o Perform Mock swim race after completing checklist to verify all inputs and outputs are working including scoreboard RTD data OmniSport 2000 Manual ED 13312 On deck Equipment lane mo...

Страница 2: ...hes knobs cabling and connections o Testing 1 Test for charger functionality by connecting to the HS 200 Charging LED should light when plugged in 2 Ensure microphone is connected to the horn start assembly Wireless models ensure belt pack has a new battery and matches the wireless channel set on the HS 200 base assembly and has the antenna mounted on the base unit 3 Set volume controls to desired...

Страница 3: ...and when pressing on the pad it should create a shorted connection 4 If the pad passes the try test it can be put in the water to complete the we test by measuring for DC voltage Wet Test 1 1 Place all touchpads into the water and connect to their lane connections 2 Turn on the OmniSport 2000 and go into swimming mode 3 Press MENU 5 2 and go into the test mode 4 Use your hand or a swimmer to tap t...

Страница 4: ...nto the lane harness and the OmniSport connected and setup in Swimming mode 3 Place your hand flat on the RTOP and hold for two seconds 4 Remove you hand quickly and the red LED will turn solid for 1 second then return back to a flashing ready state 5 The RTOP time should also be able to be captured on the OmniSport printout as long as settings event are configured correctly Relay Take off Platfor...

Страница 5: ...al cable adapter on the Pro Dive computer o Verify communication between devices May need to change com port value in Pro Dive or set to UDP o Tip When using serial connections with an Ethernet OmniSport the network port must be disabled to allow serial communications MENU 4 7 7 NETWORK PRO OFF will allow you to shut off the Network Pro option Detailed Instructions ED 16444 Hy Tek Meet Manager o V...

Страница 6: ...setups use Generic Serial for Alternative configurations CTS Timer o Verify judge console firmware is up to date 3 0 or higher JC 100 and RC 100 options o Verify base station firmware is up to date if using wireless judge consoles 3 0 or higher o Verify the base station function Function setting should be set to a 6 on version 3 0 and higher Function 1 for earlier versions o Verify the correct 900...

Отзывы: