8

For better  performance, install  a 3/8 inch quick plug(1/4 
inch NPT threads) with an inside diameter of 0.315 inch 
(8mm) on the nailer and a 3/8 inch quick coupler on the air 
hose.

With  trigger  locker  in  lock  position,  plug  compressor 
into electrical outlet.
Close pressure regulator  by turning all the way to the 
left. Turn compressor ON and let it pump all the way up 
to automatic shut-off pressure.
Attach  air  hose  to  regulator  outlet.  Adjust  pressure 
regulator by turning to the right so that outlet pressure is 

between 70PSI to 115PSI.
Load fasteners into nailer.
Point the nailer in a safe direction while attaching to air 
hose.
Turn the trigger locker in untook position.
Nailer is ready for use. You may need to adjust outlet 
pressure to achieve proper fastener depth.

1.

2.

3.

4.
5.

6.

RECOMMENDED 
HOOKUP

MINIMUM COMPONENTS 

REQUIRED FOR HOOKUP

Air  compressor:

Air  supply  hose:

  The  air  compressor  must  be  able  to 

maintain  a  minimum  of  70PSI  when  the  nailer  is  being 
used. An inadequate air supply can cause a loss of power 
and inconsistent driving.
Pressure  regulator:    A  pressure  regulator  is  required  to 
control the operating pressure of the nailer between 70PSI 
and 115PSI .

  Always  use  air  supply  hoses  with  a 

minimum working pressure rating equal to or greater than 
the pressure from the power source, or 150PSI, whichever 

is greater. Use 1/4 inch air hose for runs up to 50 feet. Use 
3/8 inch air hose for 50 feet, run or longer.

When  cleaning  a tool be  careful  not  to  disassembly  any 
portion  of  the  tool  since  internal  components  may  be 
misplaced  or  safety  components  may  be  improperly 
mounted.

 

 

 Certain cleaning agents such as gasoline, carbon 

tetrachloride, ammonia. etc. may damage plastic parts and 
o-rings.

CLEANING

WARNING

MAINTENANCE

Do not attempt to clean by inserting pointed objects through 
openings.

 

 

   

 

 

 

   

 

.

 Sharp edges may damage internal components 

causing a serious hazard.
Ventilation  openings,  the  work  contact  element,  and  the
trigger must be kept clean and free of foreign matter
Clean the magazine. Remove metal or wooden chips which 
may have accumulated in the magazine. Periodically clean 
magazine with compressed air.

WARNING

STORAGE

HOOKUP INSTRUCTIONS FOR 

TOOL TO AIR SUPPLY

When  not  in  use,  the  tool  should  be  disconnected  and 
stored in the storage case in a warm and dry place. When 

Keep out of reach of children and personnel unfamiliar with 
tool operation.

 Lock the storage area. Tools are dangerous 

in the hands of personnel unfamiliar with the tool.

WARNING

TRIGGER LOCK

The nailer is equipped with a trigger locker C.
If it is in lock position, tool is restricted to work and be safe.
When it is in un-lock position, the tool is in work status.

C

FIG. 18

tool will not be in use for an extended period, apply a thin 
coat of the lubricant to the steel parts to avoid rust.
Do not store the tool in a cold weather environment.

Содержание HSPW38

Страница 1: ...Metal Connector Nailer XR150A XR250 XR250S USERS MANUAL Failure to follow warning could result in DEATH OR SERIOUS INJURY WARNING M0301 03 12 V2...

Страница 2: ...RK AREA PERSONAL SAFETY TOOL USE AND CARE SERVICE AIR SOURCE CONTENTS CLEANING STORAGE HOOKUP INSTRUCTIONS FOR TOOL TO AIR SUPPLY IMPORTANT INFORMATION EXPLANATION OF THE NAILING ACTION GENERAL SAFETY...

Страница 3: ...WAYS WEAR EAR AND HEAD PROTECTION USE SAFETY EQUIPMENT DRESS PROPERLY STAY ALERT WATCH WHAT YOU ARE DOING AND USE COMMON SENSE WHEN OPERATING A POWER TOOL AVOID UNINTENTIONAL FIRING DO NOT OVERREACH M...

Страница 4: ...he firing head The tool can fire when re connected to an air supply The fasteners can be driven for a way from the workpiece and hit someone 1 Doing maintenance and inspection 2 Turning the Exhaust de...

Страница 5: ...80 325mm 3 74 95mm 12 305mm 5 24lbs 2 38kgs 35PCS 17 52 445mm 4 09 104mm 13 62 346mm 6 09lbs 2 77kgs 55PCS 13 330mm 4 09 104mm 13 62 346mm 5 68lbs 2 58kgs 35PCS Fastener Type FUNCTIONAL DESCRIPTION A...

Страница 6: ...ne copy of these Operating Safety Instructions Keep this publications for future reference Install a filter regulator lubricator unit and moisture trap on your air delivery system per the manufacturer...

Страница 7: ...Sequential Trip Mechanism for use when precision nail placement is necessary You must first depress the nail point where you want to drive a nail is driven completely release the trigger and lift the...

Страница 8: ...EMOVING NAILS Always disconnect tool from air supply before removing nails from magazine This avoids the risk of unintentional operation Do not disconnect air hose from the tool with finger on the tri...

Страница 9: ...cold conditions the tool will cycle slower than usual while driving the first nails The cycle rate will increase as the tool warms up Keep tool warm to avoid reduced cycle rate DO NOT USE A FROZEN TOO...

Страница 10: ...ever is greater Use 1 4 inch air hose for runs up to 50 feet Use 3 8 inch air hose for 50 feet run or longer When cleaning a tool be careful not to disassembly any portion of the tool since internal c...

Страница 11: ...r slow to cycle Tool dry lacks lubrication Broken head valve spring O ring cut or cracked gasketdamaged Exhaust blocked Trigger valve worn leaks Dirt grime builtup on driver Use stated air tool lubric...

Страница 12: ...l Check for debris collation in drive channel remove debris remove nails and replace with new strip Hole not properly located with point of nail Place nail point in metal connector hole before firing...