Press
FAN
button
to
change
the
fan
speed.
Only
low
speed
is
available
for
dehumidification
mode.
l)
On/Off
control
Press
to
start
or
stop
the
air
conditioner.
m)
Networking
Master
‐
Slave
Control
(only
master
unit
wall
pad
can
control
other
units
on
the
network)
Press
NET
button
to
enter
into
networking
control
mode.
Unit’s
display
area
blinking
indicates
the
slave
unit
under
control.
Press
TIME
or
TIME
to
select
the
desired
slave
unit;
Units
that
are
off
will
be
bypassed
automatically.
Parameters
that
can
be
controlled
are
on/off,
timer
weekly
program,
set
temperature,
mode,
fan
speed,
swing
and
sleep.
Parameter
operation
methods
are
the
same
as
above.
Press
NET
button
again
to
exit
networking
control
mode.
Hold
down
SWIN
G
and
FRESH
buttons
for
3
seconds
to
enter
into
global
control
mode.
will
light
up.
Repeat
the
same
to
exit
global
control
mode.
In
global
control
mode,
the
settings
of
the
master
unit
will
be
broadcast
to
all
the
slave
units.
n)
Unit
operation
parameters
browsing
Hold
down
CANCEL
and
FAN
buttons
for
3
seconds
to
enter
into
operation
parameters
browsing
mode.
Unit
display
area
shows
the
address
of
the
slave
unit
being
viewed.
Slave
unit
selection
method
is
the
same
as
in
networking
control
above.
Press
or
to
browse
various
parameters
as
follow:
Wall
pad
display
temperature
area
Wall
pad
display
time
area
C0
Return
air
temperature
displayed
C1
Indoor
coil
temperature
displayed
C2
DIP
switch
setting
displayed
C3
Indoor
coil
2
temperature
Press
CANCEL
button
to
exit.
o)
Error
indication
When
faulty
slave
unit
is
detected,
Master
unit
display
area
shows
the
faulty
unit
address,
time
area
shows
the
error
code
and
wall
pad
backlight
changes
to
red
color.
Should
there
be
multiple
units
having
problems,
addresses
and
error
codes
will
be
shown
one
after
another.
Error
code
definition:
Error
Error
code
Electrical
heater
faulty
E1
Indoor
coil
sensor
2
faulty
E2
Return
air
sensor
faulty
E3
Indoor
coil
sensor
1
faulty
E4
Indoor
coil
low
temperature
protection
E5
Indoor
coil
over
heat
protection
E6
Float
switch
alarm
E7
Local
communication
error
E8
Содержание FDLA-09
Страница 1: ...SK2018 GLOBAL FDLA V P AC 001 FDLA V P AC MOTOR...
Страница 27: ...Page 26 of 51 SK2018 GLOBAL FDLA V P AC 001 Configuration Settings...
Страница 53: ...FDHD V P AC MOTOR...
Страница 69: ...B 1 4 4 Electrical connections T Configuration standard version...
Страница 74: ...Wiring Diagram D 2 SK NCPDWH 001b S Configuration Full Control PCB...
Страница 76: ...Configuration Settings D 3...
Страница 111: ......
Страница 112: ...SK2019 FCSD H V P ECM 001 FCSD H V P ECM MOTOR...
Страница 140: ...Page 28 of 77 SK2019 FCSD H V P ECM 001 For 2 pipe system with modulating valve For 4 pipe systems with modulating valve...
Страница 190: ...SK2019 FCSD H V P ECM 001...
Страница 191: ...Page 1 of 59 SK2015 FMCD V EC 001 FMCD ECM MOTOR...
Страница 210: ...Page 20 of 59 SK2015 SWC V EC 001 D 1 3 Wiring Diagram SK NCSWC 001...
Страница 231: ...Page 41 of 59 SK2015 SWC V EC 001 D 3 4 Unit Network Wiring Scheme Wiring diagram for a master slave network connection...
Страница 233: ...Page 43 of 59 SK2015 SWC V EC 001 D 4 2 Wiring diagram SK NCSWC 002...
Страница 248: ...Page 58 of 59 SK2015 SWC V EC 001 Troubleshooting Guide E 4...
Страница 249: ...Page 59 of 59 SK2015 SWC V EC 001...
Страница 250: ...FSTD C V P ECM MOTOR...
Страница 256: ...Page 7 of 73 SK2015 FSTDC V P ECM 001 A 2 Unit Appearance FSTDC VAR FSTDC HAR FSTD...
Страница 278: ...Page 29 of 73 SK2015 FSTDC V P ECM 001 C 2 Wiring Diagram SK NCPFWB 001 ECM S Configuration Full Control PCB...
Страница 305: ...Page 56 of 73 SK2015 FSTDC V P ECM 001 E 4 Wiring Diagrams E 4 1 Standard Unit Wiring Diagram of SK NCPFWB 002 ECM...
Страница 322: ...Page 73 of 73 SK2015 FSTDC V P ECM 001...