GB
25
Detector in test mode
The LED lights up each time something is detected making it possible to test the range.
Triggering time delay
(factory setting)
Set for 120 s, even when something is permanently detected, the radio transmission is only
activated once every 120 s. Position recommended if there is frequent activity inside the
detection zone.
Mandatory position
(factory setting)
LED indicator status selection
(factory setting)
The LED does not light up with every detection (unless dip switch n°1 is ON).
Position recommended if there is frequent activity inside the detection zone.
Normal detector sensitivity
(factory setting)
This setting is suitable for most installations.
Anti-masking function enabled
(factory setting)
If the device is masked, the LED indicator flashes 3 times in a row every 5 seconds throughout
the duration of the fault (if dip switch n° 4 is ON).
The options are set using the 6 dip switches inside the detection module.
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
Detector in normal user mode
(factory setting)
The LED remains unlit (unless dip switch n° 4 is ON). The frequency of radio message
transmission depends on the position of dip switch n° 2.
1
2
3
4
5
6
ON
Triggering time delay
Set for 5 s, even when something is permanently detected, the radio transmission is only
activated once every 5 s.
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
LED indicator status selection
The LED lights up with every detection
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
Low detector sensitivity
This setting is recommended for difficult environmental conditions (wind, reflecting ground,
high brightness level, etc.)
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
Anti-masking function disabled
7.3 Setting the operating options
IMPORTANT: if you position dip switch 2 or
dip switch 4 to ON, the battery life will be
shortened.
factory setting
Operating option
dip switches
LED indicator