245
GB
7. Live tests
USER MODE
CAUTION: the high output sound power of the siren can cause hearing disorders, it is suggested taking precautions during the tests and
warning participants and persons in the close vicinity.
ATTENTION: the interval between
each transmission of an alarm
depends on the programmed period
of “inhibition of alarm” of the beam
modules.
1.
With the control panel in “User” mode:
2.
Close all the protected zones and
wait a minimum of 90 seconds.
3.
Command the control panel ON/Armed:
ƒ
• the control panel responds
“Beep, ON”
4.
Wait for the end of the programmed Exit delay
ƒ
• the control panel announces
“ON”
5.
Break/interrupt the dual beams of the barrier
under test
ƒ
• the control panel changes to
intrusion, prealert,
deterrence or warning
, depending upon the
programming.
6.
Let the control panel siren sound for 5 seconds
then disarm /switch OFF the system.
ƒ
• on receiving the
OFF
command the control panel
announces “OFF” and the current date and time,
intrusion detector “X” group “Y”.
(
(
(
(
(
(
(
(
(
(
“Beep, ON”
“ON”
“Beep, OFF,
2 1 2013
at 16 hours 30,
intrusion detector
4, group 1”
installer code