244
GB
6.3 Radio connection test
2. Break both beams of each dual beam barrier.
At each break (and detection) the control panel announces:
“Bip, deterrence detector X”
(depending on the configuration).
3.
Position the micro-switches using the table at stage 1 above.
4.
Close the covers of the modules.
1.
To facilitate efficient & rapid testing, position the micro-switches, 1 of the transmitter and 3 of the receiver to “OFF” (see table
below).
CAUTION: if you leave the micro-switches 1 of transmitter and 3 of the receiver on OFF, battery life will be reduced.
A.
Hang the cover from the top.
B.
Latch the cover closed.
C.
Tighten the fixing screw.
C
B
A
CAUTION: in order to avoid
tamper faults check the cover
is correctly closed.
ON
OFF
ON
OFF
Transmitter
Receiver
Transmission repetition period
Radio transmission activated every 2 seconds
ON
OFF
ON
OFF
When setting at 120 seconds in the event of
permanent detection/beam interrupted the radio
transmission is activated only once per period of
120 s.
This setting is recommanded when there is
frequent legitimate passage through the barrier
when the alarm system is OFF.