1.  SAFETY PRECAUTIONS 

Please make sure you review each precaution carefully. 

Pay special attention to the following statements.  

 

“WARNING” indicates a strong possibility of severe personal injury or 

loss of life, if instructions are not followed. 

 

“CAUTION” indicates a possibility of personal injury or equipment 

damage, if instructions are not followed.

 

 

 

: EXHAUST PRECAUTIONS

 

 

 Never inhale exhaust gases. 

 They contain carbon monoxide, a colorless, odorless and 

extremely dangerous gas, which can cause unconsciousness 
or death. 

 Never operate the pump indoors or in poorly ventilated areas, 

such as tunnels, caves, etc. 

 Exercise extreme care, when operating the pump near people 

or animals. 

 Keep the exhaust pipe free of foreign objects. 

 

: REFUELING PRECAUTIONS

 

 

 Be sure to stop the pump prior to refueling. 

 Do not overfill the fuel tank. 

 If fuel is spilt, wipe it away carefully and wait until the fuel has 

dried before starting the engine.  

 After refueling, make sure that the fuel cap is secured to 

prevent spillage. 

 

: FIRE PREVENTION

 

 

 Do not operate the pump while smoking or near an open 

flame. 

 Do not use around dry bushes, twigs, cloth rags, or other 

flammable materials. 

 Keep cooling air intake (recoil starter area) and muffler side of 

the engine at least 1 meter (3feet) away from buildings, 
obstructions and other burnable objects. 

WARNING 

CAUTION

WARNING 

WARNING 

WARNING 

Содержание PTD Series

Страница 1: ...PTD Diesel Engine Pump FHG DY Pump PTD Series 206 206S 306 306S 406 406S 206T 206TS 306T 306TS 405T 405TS...

Страница 2: ...1 A 2 A B C D 3 A B C D E 2 3 1 4 10 11 12 5 7 1 2 3 6 8 9...

Страница 3: ...ant efforts to improve our products certain procedures and specifications are subject to change without notice Always provide us the Model Name and Serial No of your pump when ordering spare parts Ple...

Страница 4: ...as such as tunnels caves etc Exercise extreme care when operating the pump near people or animals Keep the exhaust pipe free of foreign objects REFUELING PRECAUTIONS Be sure to stop the pump prior to...

Страница 5: ...ot transport the pump with fuel in the tank or with fuel strainer valve open Keep the unit dry do not operate it in rainy conditions PRE OPERATION CHECKS Carefully check fuel hoses and joints for loos...

Страница 6: ...1 to 6 indicated in the sentence See Fig 1 A Plug Drain Suction inlet Delivery outlet Air cleaner Fuel injection pump Speed control Stop lever Casing Fuel tank Fuel filter inside Plug Priming Muffler...

Страница 7: ...ng the engine under following conditions a Starting the brand new engine for the first time b Restarting the engine after the engine has stopped due to fuel shortage Air discharging procedure See Fig...

Страница 8: ...nce will be felt then return the handle to its original position d Lift down decompression lever See Fig 7 A Down e Pull briskly Do not pull out the rope completely CAUTION Be sure to pull the recoil...

Страница 9: ...the engine temperature to rise abnormally Run the starting motor for long time will cost the battery power greatly even burn out the motor Always leave the starting key at ON position while the engine...

Страница 10: ...d be performed after the first twenty 20 hours of operation Thereafter change oil every hundred 100 hours Before changing the oil check for a suitable way to dispose of the old oil Do not pour oil dow...

Страница 11: ...to the upper level mark of the oil gauge See Fig 3 C e Reinstall the oil gauge firmly CAUTION Do not use gasoline engine oil Use diesel engine oil only 4 SERVICING THE AIR CLEANER Dirty or clogged ai...

Страница 12: ...ilt the pump and drain all water from the delivery hole Severe damage to the pump may occur if water freezes in the pumping chamber 3 DISCHARGE FUEL Remove the drain screw of the fuel tank See Fig 3 D...

Страница 13: ...ME Air suction at suction side Check piping at suction side Insufficient amount of priming water inside the pump casing Prime sufficiently Loose tightening of the drain plugs Tighten the plugs firmly...

Страница 14: ...Specifications are subject to change without notice PTD206 PTD405TS Fuel Tank Capacity Starting System Recoil Starter Recoil Electric Starter Model Type Forced Air cooled 4 stroke Diesel engine Fuel D...

Страница 15: ...bricating Method Applicable Lubricant Oil Lubricant Oil Capacity L 0 75 1 1 Fuel Oil 200 19 6 Diesel 5 5 MODEL TYPE Single cylinder 4 stroke vertical air cooled diesel engine Cumbustion System Direct...

Страница 16: ...4 A OPEN CLOSE 5 A B 6 7 A UP DOWN STOP IDLE START...

Страница 17: ...holes in battery support tubes 50 Install four bolts 56 and four nuts 57 Tighten all fasteners 4 Attach the top of the battery support tube in two nuts 57 of the U bolt 53 5 Repeat step 4 for second...

Страница 18: ...1520 1 Funatsuke Yoro cho Yoro gun Gifu 503 1382 Japan Phone 81 584 36 0501 Fax 81 584 36 0504 URL http www daishin japan co jp E mail overseas daishin japan co jp P No 205002263...