PIM-00004
△
1
[Operation Manual]
51/61
DAIKIN INDUSTRIES, LTD.
Return filter element replacement procedure
When the detector indicates clogging of the filter (the indicator ring floats up, and the green area of the
indicator column is completely hidden), replace the filter element according to the following procedure:
1.
Loosen the hexagon socket head bolts [1] that fasten the cover [3], and pull up the cover. Then, the
element [5] can be removed.
2.
Pull out the split pin [10] from the element, loosen the element tightening nut [9], and remove the parts [6]
to [8].
3.
Replace the element with a new one, and re-mount it by following the above procedure in reverse.
4.
Tighten the hexagon socket head bolts [1] securely in the diagonal order.
[1] Hexagon socket head bolt
[2] Plain washer
[9] Element tightening nut
[3] Cover
[4] Packing
[5] Element
[8] Spring washer
[11] O-ring
[10] Split pin
[7] Plain washer
[6] Packing