SiENBE04-808_A
Indoor Unit
Removal Procedure
180
1.9
Removal of Fan Motor
Procedure
Warning
Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step
Procedure
Points
1. Remove the right side
panel.
Preparation
Remove the indoor heat
exchanger according to the
“Removal of Indoor Heat
Exchanger”.
1
Remove the 2 screws
and remove the right
side panel.
2
Release the fan motor
wire harness from the
hook.
(R8112)
(R8113)
Right side
panel
(R8114)
(R8115)