SiENBE04-808_A
Indoor Unit
Removal Procedure
174
2. Remove the indoor heat
exchanger.
Preparation
Remove the indoor unit from
the installation plate.
1
Unfasten the hook of
the piping fixture at the
back of the indoor unit
and pull out the pipe.
2
Widen the auxiliary pipe
by about 10-20
degrees.
Caution
When dismounting or
mounting the indoor heat
exchanger, be sure to wear
gloves or wrap it with cloth
before proceeding. (You may
be injured by the fins.)
3
Remove the 2 screws
on the left side.
4
Unfasten the lower
hook on the right side
with a flat screwdriver.
Step
Procedure
Points
(R10622)
Piping
fixture
(R10543)
Unbending angle:
10-20 deg.
(R10546)
(R10326)
Lower hook
SiENBE04-808_A.pdf 186
21/02/2011 13:20:07
Содержание Super Multi NX FTXS20G2V1B
Страница 13: ...SiENBE04 808_A 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 Cooling Only 2 1 2 Heat Pump 3...
Страница 17: ...SiENBE04 808_A 5 Specifications Part 2 Specifications 1 Specifications 6 1 1 Cooling Only 6 1 2 Heat Pump 9...
Страница 297: ...Outdoor Unit RK X S50G2V1B ARXS50G2V1B SiENBE04 808_A 285 Removal Procedure...