SiENBE04-808_A
Indoor Unit
Removal Procedure
170
4. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 3 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
2
Disconnect the
connector [S26] from
the INTELLIGENT EYE
sensor PCB.
5. Remove the signal
receiver PCB.
1
Unfasten the 3 hooks
and remove the signal
receiver PCB.
2
Disconnect the
connector [S48] from
the signal receiver
PCB.
Step
Procedure
Points
(R8092)
INTELLIGENT EYE
sensor PCB
(R8093)
[S26]
(R8090)
Signal
receiver
PCB
(R8091)
[S48]
SiENBE04-808_A.pdf 182
21/02/2011 13:20:06