SiBE05-722EE
Main Functions
Functions and Control
37
How to Set the Temperature and Airflow Rate
When using HOME LEAVE operation for the first time, set the temperature and airflow rate for
HOME LEAVE operation. Record your preferred temperature and airflow rate.
1. Press the
HOME LEAVE
button.
Make sure
is displayed on the remote controller display.
2. Adjust the temperature with
or
as you like.
3. Adjust the airflow rate with the
FAN
setting button as you like.
HOME LEAVE operation will run with these settings the next time you start HOME LEAVE
operation. To change the recorded information, repeat steps 1 – 3.
Others
The set temperature and airflow rate are memorized in the remote controller. When the
remote controller is reset due to replacement of battery, it is necessary to set the
temperature and airflow rate again for HOME LEAVE operation.
The operation mode cannot be changed while HOME LEAVE operation is being used.
1.10 Inverter POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, the air conditioner can be
operated by increasing the indoor fan rotating speed and the compressor frequency.
Detail
When the
POWERFUL
button is pressed, the fan speed and target temperature are converted
to the following states for 20 minutes.
A
= 50 rpm
Ex: POWERFUL operation in cooling
Note:
POWERFUL Operation cannot be used together with OUTDOOR UNIT QUIET Operation.
Initial setting
Selectable range
Temperature
Airflow rate
Temperature
Airflow rate
Cooling
25°C
18 ~ 32°C
5 steps,
,
Heating
25°C
10 ~ 30°C
5 steps,
,
Operation mode
Fan speed
Target temperature
COOL H
tap
+
A
rpm
18°C
DRY
Dry rotating speed +
A
rpm
Lowered by 2.5°C
HEAT
H tap +
A
rpm
30°C
FAN
H tap +
A
rpm
—
AUTO
Same as cooling / heating in
POWERFUL operation
The target temperature is
kept unchanged.
(R19177)
Target temp.
Fan
A
rpm
18˚C
H tap
Set tap
20 minutes
It should be the lower limit of
cooling temperature.
It counts 20 minutes also
in the remote controller.
POWERFUL
ON
POWERFUL
OFF
Ending condition:
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.