19
Product description
EN
RoCon UFH
Table 4-5: Technical specifications timer module
Parameter
Timer module RoCon UFH-UM
General specifications
Dimensions (W x H x D)
37 mm x 93 mm x 28 mm
Weight
33 g
Housing material
ABS
Temperature reduction
4K
Functions
Timing
Date, time, weekday
(leap year detection, switching between
daylight saving time and winter time)
Switching channels for temperature
reduction
2, independently programmable
Memory blocks for temperature reduc-
tion
9, independently programmable
Valve and pump protection function
0 to 15 min, adjustable
Additional pump running time
0 to 15 min, adjustable
Operating modes day, night, timer
Day
Heating control without temperature reduc-
tion
Night
Heating control with permanent tempera-
ture reduction
Timer
Heating control with temperature reduction
according to programmed switching times
Operating temperature range
Ambient
-10 … 60 °C
Storage
-10 … 60 °C
Max. humidity
Non-condensing
Supply voltage
Nominal voltage
Via base module 3.3 V DC
Nominal power
3 mW
Battery power
> 3 months
Electrical safety
Degree of protection (EN 60529)
IP 30
Electromagnetic compatibility (EMC)
Emitted interference/immunity
EN 61326-1:2013
Содержание RoCon UFH
Страница 2: ......
Страница 27: ...25 Mounting EN RoCon UFH 6 Refit the cover and close it Fig 5 5 Closing the cover ...
Страница 64: ......
Страница 89: ...25 Montage DE RoCon UFH 6 Hängen Sie die Abdeckung ein und schließen diese Bild 5 5 Abdeckung schließen ...
Страница 126: ......
Страница 151: ...25 Montage FR RoCon UFH 6 Accrocher le couvercle et le fermer Fig 5 5 Fermer le couvercle ...
Страница 188: ......
Страница 213: ...25 Montage NL RoCon UFH 6 Haak de afdekking vast en sluit haar Afb 5 5 Afdekking sluiten ...
Страница 250: ......
Страница 275: ...25 Installazione IT RoCon UFH 6 Agganciare la copertura e chiuderla Fig 5 5 Chiusura della copertura ...
Страница 312: ...008 1706699 00 12 2020 Copyright Daikin www daikin eu ...