SiUS041111
Troubleshooting with LED
Service Diagnosis
73
1. Troubleshooting with LED
1.1
Indoor Unit
Operation Lamp
The operation lamp blinks when any of the following errors is detected.
1. When a protection device of the indoor or outdoor unit is activated, or when the thermistor
malfunctions.
2. When a signal transmission error occurs between the indoor and outdoor units.
In either case, conduct the diagnostic procedure described in the following pages.
Service Monitor
The indoor unit has one green LED (LED A) on the control PCB. When the microcomputer works in
order, the LED A blinks.
1.2
Outdoor Unit
The outdoor unit has one green LED (LED A) on the main PCB. When the microcomputer works in
order, the LED A blinks.
09/12 class
15/18/24 class
(R11599)
Operation lamp
(green)
(R14251)
Operation lamp (green)