Outdoor Unit: 09/12 Class
SiUS041111
178
Removal Procedure
4
Disconnect the relay
connector for the
compressor motor.
5
Release the harnesses
from the hook.
6
Unfasten the hook of
the electrical box from
the partition plate with a
flat screwdriver.
The electrical box can be
removed by lifting itself without
a screwdriver.
Step
Procedure
Points
(R11774)
(R11775)
(R7318)