Indoor Unit: 09/12 Class
SiUS041111
142
Removal Procedure
4
Disconnect the
terminals from the
terminal board with
pliers.
1
: black, upper
2
: white, lower
3
: red, upper
: green without sleeve, upper
green with sleeve, lower
5
Release the 4 hooks.
Lift up the upper part of
the control PCB and
remove it.
6
The figure shows the
control PCB.
Refer to page 13 for detail.
[S6]: swing motor
[S26]: display PCB
[S32]: indoor heat exchanger
thermistor
[S200]: fan motor
[S403]: adaptor PCB (option)
Step
Procedure
Points
(R11656)
(R11943)
Control
PCB
Hook
Hook
S32
S200
S24
S26
(R8013)
[S26]
[S6]
[S403]
[S32]
[S200]
Fuse