4
|
Components
Service manual
164
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
b
a
c
c
b
a
Screw
b
Wiring box cover
c
Tabs
To remove the switch box
ATXM-R and FTXM-R units
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
153].
1
Disconnect the power supply wiring from the power supply terminal X1M.
2
Remove the screw and power supply wiring bracket.
3
Pull the clip and remove the heat exchanger thermistor from its holder.
4
Remove the screw to disconnect the grounding wire from the heat exchanger.
c
f
b
a
d
A
e
A
Class 20~42 unit
a
Power supply terminal X1M
b
Power supply wiring bracket
c
Screw (ground wire)
d
Indoor unit main PCB
e
Switch box screw
f
Switch box