![Daikin Perfera RXM20R Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072113.webp)
4
|
Components
Service manual
113
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
a
A
b
A
Floor standing indoor unit
a
Black wire
b
White wire
Is the measured voltage on the indoor
unit power PCB correct?
Action
Yes
Return to
112] of the indoor unit
power PCB and continue with the next
procedure.
No
Continue with the next step.
3
Check the power supply to the indoor unit, see
205].
Is the power supply to the indoor unit
correct?
Action
Yes
Correct the wiring between the power
supply terminal of the indoor unit and
the indoor unit power PCB, see
117].
No
See "To check the power supply to the
indoor unit" (
206]) for the next steps.
To perform an electrical check of the indoor unit power PCB
Prerequisite:
First perform a power check of the indoor unit power PCB, see
112].
1
Measure the voltage between the pins 1‑4 of the connector S102.
Result:
The measured voltage MUST be 324 VDC.