![Daikin Perfera RXM20R Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072146.webp)
4
|
Components
Service manual
146
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
2
Disconnect the DC fan motor connector from the main PCB.
e
d
d
a
c
b
a
DC fan motor connector
b
DC fan motor harness
c
Switch box
d
Screw
e
DC fan motor assy
3
Detach the DC fan motor harness from the switch box.
4
Slightly bend the harness retainers (if applicable) to detach the DC fan motor
harness.
5
Remove the 4 screws that fix the DC fan motor assembly.
6
Remove the DC fan motor assembly from the unit.
7
To install the DC fan motor assembly, see
145].
To install the DC fan motor assembly
1
Install the DC fan motor assembly in the correct location.
2
Fix the DC fan motor assembly to the unit by tightening the screws.
e
d
d
a
c
b
a
DC fan motor connector
b
DC fan motor harness
c
Switch box
d
Screw
e
DC fan motor assy
3
If applicable: Route the DC fan motor harness through the harness retainers
and bend the harness retainers to attach the DC fan motor harness.