UNIT1
(Plasma ioniser)
UNIT2
(Streamer unit)
19
Cleaning of UNIT1 and UNIT2
Time for
cleaning
UNIT1:
If the “UNIT1” lamp lights
UNIT2:
Once every 3 months or if
the “UNIT2” lamp lights
Cleaning
method
Soak, drain and dry
Wipe
If marking is a concern, clean the unit even if the “UNIT1” and “UNIT2”
lamps do not light.
For details on removing and attaching each part,
see
►
Page 17.
.
Ionising frame
Streamer unit
Ionised wire (rear)
Opposing pole
plates
Procedure
UNIT1
UNIT2
Notes
Ionising frame / Ionised wire
Opposing pole plates
Streamer unit
Remove the parts.
►
Page 9.
►
Page 17, 18.
►
Page 18.
Open the front panel and pull out
the streamer unit.
Use a vacuum cleaner to remove the
dust.
• Do not remove the screws from the ionising frame or UNIT2.
This may lead to damage.
Soak in lukewarm water or water.
(About 1 hour)
• Clean UNIT1 and UNIT2 somewhere which can be wet such as in a shower room or
kitchen sink.
• For stubborn dirt, soak UNIT1 and UNIT2 in lukewarm water or water in which neutral
liquid detergent (i.e., kitchen cleaner, etc.) has been dissolved.
• Use the amount of neutral liquid detergent indicated in the instructions for the detergent.
• Do not use powdered, alkaline or acidic cleaner, and do not rub with hard brushes, etc.
Doing so may cause deformation, damage, or rust.
• If the needles inside UNIT2 are deformed, deodorising capacity diminishes.
Remove dirt with a piece of cloth, soft
brush, etc.
Wear rubber
gloves.
Wear rubber gloves.
Cloth
Cotton
swab
Wipe
1) Ionising frame
2) Ionised wire
For details,
Rub
Wear rubber gloves.
Cloth
Brush
Wear rubber gloves.
Cloth
Cotton
swab
Wipe
3) Streamer unit
For details,
Rinse in running water and drain.
• If detergent remains on UNIT1 or UNIT2, the “UNIT1” and “UNIT2” lamps do not go off
after cleaning, therefore rinse off the detergent well.
• Do not leave any lint from cleaning cloths behind. Lint may lead to malfunctions.
Dry in a well-ventilated, shaded
place. (About 1 day)
• Plastic parts may deform or discolour if exposed to direct sunlight.
• If water remains on UNIT1 or UNIT2, even in small quantities, the “UNIT1” and “UNIT2”
lamps do not go off after cleaning, therefore dry them throughly in the shade.
Attach the parts.
►
Page 10.
►
Page 17, 18.
►
Page 18.
Reattach the streamer unit as before.
1) Ionising frame
(Remove dirt after soaking
but before drying.)
• Remove dirt from plastic
parts with a soft piece of
cloth.
• Use a cotton swab, etc. to
wipe away dirt in recesses
and places where fi ngers do
not fi t.
• Do not leave any lint from
cleaning cloths behind. Lint
may lead to malfunctions.
Wear rubber
gloves.
* Remove dirt from recesses with
a cotton swab, etc.
2) Ionised wire
(8 locations)
• Remove dirt from the ionised wires and
surrounding plastic parts with a soft
piece of cloth.
* Wipe the ionised wires gently.
Pulling on them forcefully may cause
them to snap.
Wear rubber
gloves.
Clean the ionised wires
without dislodging them
from the V-groove.
3) Streamer unit
• Wipe the needles lightly with
a soft piece of cloth such as a
cotton swab moistened with
water or neutral liquid
detergent if dust is adhered
to them.
• Remove dirt from plastic
parts (
) and metal parts
in internal areas with a cotton
swab or a soft piece of cloth.
• Do not remove the screws.
* If the needles are deformed,
deodorising capacity diminishes.
Wear rubber
gloves.
: Plastic parts
Wipe the needles
gently from the
base to the tip.
Do not touch
the needles.
Cotton swab
01_EN_3P276413-4F.indd 19
8/1/2012 11:29:54 AM