Daikin mc70mvm6 Скачать руководство пользователя страница 22

21

Time for 

cleaning

When the fi lter lamp in the 

display lights up or blinks

It is not necessary to replace the pleated fi lter 
until the fi lter lamp lights up or blinks.

Cleaning 

method

Replace

Deodorising 
catalyst unit

Front panel

UNIT1

Pleated fi lter

Remove the front panel and UNIT1. 

 

Page 17.

Replace the pleated fi lter with a new 
fi lter.

1) Remove the used pleated fi lter.

• Release the pleated fi lter from the projections 

(5 each on the right and left) of the deodorising catalyst 
unit (front side).

2) Take out a new pleated fi lter from the fi lter 

container and then attach it to the deodorising 
catalyst unit.

• Fit the holes (5 each on the right and left) of the 

pleated fi lter onto the tabs on the right and left of the 
deodorising catalyst unit.

• Insert the pleated fi lter underneath the tabs 

(4 locations at the top and bottom) of the deodorising 
catalyst unit. 

Projection 
(5 each on right and left)

Pleated fi lter

Deodorising 
catalyst unit

Top and 
bottom tabs 
(4 locations)

Face the white 

side to the front.

Attach UNIT1 and the front panel. 

 

Page 17.

Connect the power plug.

Press the fi lter reset button on the upper 
part of the front panel for 5 seconds. 

(The fi lter lamp goes off with a short beep sound.) 

Filter reset button

• Even if the pleated fi lter is replaced, the fi lter lamp does 

not go off unless you press the fi lter reset button for 
5 seconds.

NOTE

• Order the pleated fi lter for replacement from your dealer.
• Replace the pleated fi lter when the fi lter lamp lights up or blinks 

even if the fi lter looks clean. The amount of visible dirt does not 
represent the capacity of the fi lter.

• The replacement interval for the pleated fi lter varies according to 

how the unit is used and where it is located.
The fi lter lamp lights up after about 2 years if the unit is used 
every day in a house where 10 cigarettes per day are smoked.
(The replacement interval shortens when the unit is used where 
the air is particularly dirty.)

• When you have replaced the pleated fi lter before the fi lter lamp 

lights up because of visible dirt or generation of odour, press the 
fi lter reset button for 5 seconds.

Options

ATTENTION

• For replacement pleated fi lters contact the service shop.

Part

Model

Pleated filter 5 pcs.

KAC017A4E

• If the unit is used with dirty parts

• Air is not cleaned.
• Odors are not removed.
• Unnecessary odors may be generated.

• Discard of the pleated fi lters as noncombustible waste.

Replacement of the Pleated Filter

01_EN_3P276413-4F.indd   21

8/1/2012   11:29:59 AM

Содержание mc70mvm6

Страница 1: ...Air Puri er OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70MVM6...

Страница 2: ...hat readily settles because of its large particle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes adsorbed odour The decomposition cycle that main...

Страница 3: ...g environment These cases are also not operational issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operati...

Страница 4: ...o electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by humidity or other factors may lead to fir...

Страница 5: ...r supply cord and pull to disconnect the unit Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from...

Страница 6: ...the unit where pets are kept be careful that pets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconne...

Страница 7: ...ores the accessory remote controller when not in use Remote controller Power plug Power supply cord Holds 4 replacement pleated filters Page 9 Filter container Front panel Ventilation fan Ionised wire...

Страница 8: ...nness level 1 Operation directly after attaching the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the sett...

Страница 9: ...ter reconnecting the power plug If the odour level remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types o...

Страница 10: ...How to attach the pleated filter Make sure to attach the pleated filter before starting operation 1 Remove the front panel Push the 2 clips right and left and pull the front panel upward and remove i...

Страница 11: ...the deodorising catalyst unit by the handles fit the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deod...

Страница 12: ...ontrols unevenness in the room temperature while cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside...

Страница 13: ...a battery is swallowed make sure to contact a doctor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combu...

Страница 14: ...gage the childproof lock You can release the childproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds...

Страница 15: ...automatically resume operation when the power plug is connected next time Auto fan operation The airflow rate is automatically selected from Quiet Low Standard or High according to the uncleanness le...

Страница 16: ...it because the UNIT1 lamp may light up if any water drops remain on the prefilter Use a vacuum cleaner to remove the dust Soak in lukewarm water or water About 1 hour Dry throughly after soaking Care...

Страница 17: ...with a cloth moistened with neutral detergent Do not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odou...

Страница 18: ...tions into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising cataly...

Страница 19: ...me Pinching the sets of knobs on the right and left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green...

Страница 20: ...soft brush etc Wear rubber gloves Wear rubber gloves Cloth Cotton swab Wipe 1 Ionising frame 2 Ionised wire For details Rub Wear rubber gloves Cloth Brush Rinse in running water and drain Dry in a we...

Страница 21: ...ge or rust If the needles inside UNIT2 are deformed deodorising capacity diminishes Wear rubber gloves Cloth Cotton swab Wipe 3 Streamer unit For details If detergent remains on UNIT1 or UNIT2 the UNI...

Страница 22: ...n the upper part of the front panel for 5 seconds The filter lamp goes off with a short beep sound Filter reset button Even if the pleated filter is replaced the filter lamp does not go off unless you...

Страница 23: ...ds reconnect the power plug and try the operation again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reac...

Страница 24: ...ion Can the deodorising catalyst unit be washed with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it wi...

Страница 25: ...e is odour the green lamp remains lit Is a large amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of th...

Страница 26: ...en if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off Page 21 Other There is a burn mark on the metal part of UNIT2 This is a mark...

Страница 27: ...26 MEMO...

Страница 28: ...3P276413 4F M11B332B 1208 HT Two dimensional bar code is a code for manufacturing...

Отзывы: