background image

24

Troubleshooting

Before consulting your dealer or asking for repairs, check the following points. 

 

If the problems still can not be solved, consult your dealer.

The unit does not operate.

The unit does not operate 

even if the ON / OFF button is 

pressed.

 

Is the front panel correctly set? 

 

Page 10.

 

Are the projections on the rear of the front panel broken?

 Check the projections. 

 

Page 16.

  

Consult your dealer if the projections are broken.

 

Is the battery of the remote controller run down? 

 

Page 12.

The desired results are not obtained.

The air is not cleaned.

 

Is the unit located where the air does not reach the entire room 

or is something obstructing the airflow? 

 Select an unobstructed location from where the air can reach the 

entire room.

 

Is the prefilter, the pleated filter or UNIT1 dirty?

 Perform cleaning. 

 

Page 15-21.

 

If odour of the deodorising catalyst unit is a concern, lightly wet 
the surface of the unit using an atomiser, and then dry it in a 
shaded and well-ventilated place.

Although there is odour, the 
green lamp remains lit.

 

Is a large amount of odour generated when starting operation of 

the unit?

 The odour level of the initial 1 minute is used as the standard for 

the sensitivity of the odour sensor. Operate the unit with an 
increased airflow. 

 

Page 8.

 

Modify the standard sensitivity of the odour sensor using the 
following procedure.  
When the air is clean (when there is no odour), disconnect the 
power plug and wait for 3 or more seconds. Connect the power 
plug once again, and start operation.

Odour comes from the air 
outlet.

 

Is a large amount of odour generated temporarily? (i.e., many 

people are smoking, grilling meat, etc.)

 Operate the unit and the odour should gradually go away.

 

Have you moved the unit from another room?

 The original room may have an odour. 

Operate the unit for a while.

 

Are odours constantly generated in the room? (i.e., paint, new 

furniture, wall paper, sprays, cosmetics, chemicals, etc.)

 As odour that is constantly generated can not be completely 

removed, use the ventilation system in the room or operate the 
unit in a well-ventilated room for a while.

 

You may smell an odour as ozone particles are generated.  
The amount is negligible, so it does not harm your health.

01_EN_3P276413-4F.indd   24

8/1/2012   11:30:01 AM

Содержание mc70mvm6

Страница 1: ...Air Puri er OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70MVM6...

Страница 2: ...hat readily settles because of its large particle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes adsorbed odour The decomposition cycle that main...

Страница 3: ...g environment These cases are also not operational issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operati...

Страница 4: ...o electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by humidity or other factors may lead to fir...

Страница 5: ...r supply cord and pull to disconnect the unit Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from...

Страница 6: ...the unit where pets are kept be careful that pets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconne...

Страница 7: ...ores the accessory remote controller when not in use Remote controller Power plug Power supply cord Holds 4 replacement pleated filters Page 9 Filter container Front panel Ventilation fan Ionised wire...

Страница 8: ...nness level 1 Operation directly after attaching the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the sett...

Страница 9: ...ter reconnecting the power plug If the odour level remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types o...

Страница 10: ...How to attach the pleated filter Make sure to attach the pleated filter before starting operation 1 Remove the front panel Push the 2 clips right and left and pull the front panel upward and remove i...

Страница 11: ...the deodorising catalyst unit by the handles fit the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deod...

Страница 12: ...ontrols unevenness in the room temperature while cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside...

Страница 13: ...a battery is swallowed make sure to contact a doctor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combu...

Страница 14: ...gage the childproof lock You can release the childproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds...

Страница 15: ...automatically resume operation when the power plug is connected next time Auto fan operation The airflow rate is automatically selected from Quiet Low Standard or High according to the uncleanness le...

Страница 16: ...it because the UNIT1 lamp may light up if any water drops remain on the prefilter Use a vacuum cleaner to remove the dust Soak in lukewarm water or water About 1 hour Dry throughly after soaking Care...

Страница 17: ...with a cloth moistened with neutral detergent Do not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odou...

Страница 18: ...tions into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising cataly...

Страница 19: ...me Pinching the sets of knobs on the right and left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green...

Страница 20: ...soft brush etc Wear rubber gloves Wear rubber gloves Cloth Cotton swab Wipe 1 Ionising frame 2 Ionised wire For details Rub Wear rubber gloves Cloth Brush Rinse in running water and drain Dry in a we...

Страница 21: ...ge or rust If the needles inside UNIT2 are deformed deodorising capacity diminishes Wear rubber gloves Cloth Cotton swab Wipe 3 Streamer unit For details If detergent remains on UNIT1 or UNIT2 the UNI...

Страница 22: ...n the upper part of the front panel for 5 seconds The filter lamp goes off with a short beep sound Filter reset button Even if the pleated filter is replaced the filter lamp does not go off unless you...

Страница 23: ...ds reconnect the power plug and try the operation again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reac...

Страница 24: ...ion Can the deodorising catalyst unit be washed with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it wi...

Страница 25: ...e is odour the green lamp remains lit Is a large amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of th...

Страница 26: ...en if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off Page 21 Other There is a burn mark on the metal part of UNIT2 This is a mark...

Страница 27: ...26 MEMO...

Страница 28: ...3P276413 4F M11B332B 1208 HT Two dimensional bar code is a code for manufacturing...

Отзывы: