3-22
11. BASIC FUNCTION SETTING MODE
(Continued from the previous page)
Make selection using the key
and key. Press the key to
determine the selection.
Make selection using the key
and key. Press the key to
determine the selection.
ON
: Turning-off function available
OFF: Turning-off function not available
33 : Unloader system available
100: Unloader system not available
ON
: Dehumidification coil available
OFF: Dehumidification coil not
available
diSP
COMP
REHEAT
OFF: Detection function not available
H
: Detection function available at
the upper ventilator
L
: Detection function available at
the lower ventilator
FA SEN
Make selection using the key and
key. Press the key to
determine the selection.
Note: If turned "ON", the LED display
becomes unlit by pressing the
key twice.
0/
CHART
Make selection using the key
and key. Press the key to
determine the selection.
Note: "33" is applicable only for
LXE10D.
S
S
S
S
Detection of ventilation amount
(FA log) function setting
Setting LED indicator lamp
turning-off function available
or not available
Setting of dehumidification
coil available or not available
Compressor unloader
system setting
03̲LXE10E100以降(13-26)̲E.qx 08.8.28 5:51 PM ページ 3-22
https://daikin-p.ru
Содержание LXE10E100
Страница 135: ...5 7 An example of installation of CA devices inside q TransFRESH ASS Y A4 A5 CABLES W MOUNTING BOX q https daikin p ru ...
Страница 170: ...7 12 Schematic wiring diagram LXE10E136 7 8 https daikin p ru ...
Страница 171: ...7 9 7 9 7 13 Stereoscopic wiring diagram LXE10E136 https daikin p ru ...