5-4
5.2 USDA transportation
If USDA receptacles and sensors (Optional) are provided to the unit, the unit can take USDA
transportation. (Refer to arrangement of main component in clause 2.2.2.)
5.2.1 Type of USDA sensor/receptacle
Two types of sensors can be installed, according to the type of receptacles.
User should confirm the type of receptacles and select proper sensor in below table.
According to the model, the quantity of receptacle is different. (3 or 4)
*3 receptacles : USDA 1, USDA 2, USDA 3
4 receptacles : USDA 1, USDA 2, USDA 3, CTS (Cargo temperature sensor)
5.2.2 Initial setting
User should confirm initial setting of controller as below.
1) USDA transportation: Optional function setting mode described in page 3-20
Quantity of receptacles should be set
2) USDA sensor type: Optional condition function setting mode described in page 3-23
Type of USDA sensor should be set.
5.2.3 USDA sensor calibration
USDA requires sensor calibration every transportation and report each offset figure. Free-supply
downloading software enable to assist this. Please refer to "Operation manual for Daikin Container
Communication Software".
5.2.4 USDA transportation requirement
Cargo and refrigeration unit shall be required pre-cooling before cargo loading. As to position of USDA
sensors and operation, please refer to the guidance of USDA.
5.2.5 USDA report required by USDA local officer
Free supply downloading software enables you to make document easily, which USDA local officer
requires. In detail, please refer to "Operation manual for Daikin Container Communication Software".
Type
Receptacle
Sensor
1
C016 30G006 20012
ST9702-1
2
HD10-3-96P
NTC type probe
05̲LXE10E100以降(1-8)̲E.qx 08.8.13 7:04 PM ページ 5-4
https://daikin-p.ru
Содержание LXE10E100
Страница 135: ...5 7 An example of installation of CA devices inside q TransFRESH ASS Y A4 A5 CABLES W MOUNTING BOX q https daikin p ru ...
Страница 170: ...7 12 Schematic wiring diagram LXE10E136 7 8 https daikin p ru ...
Страница 171: ...7 9 7 9 7 13 Stereoscopic wiring diagram LXE10E136 https daikin p ru ...