SiUS091133
Check
Service Diagnosis
142
5. Check
5.1
Thermistor Resistance Check
Check No.01
Disconnect the connectors of the thermistors from the PCB, and measure the resistance of each
thermistor using tester.
The relationship between normal temperature and resistance is shown in the table and the graph
below.
The data is for reference purpose only.
The room temperature thermistor is directly mounted on the display PCB. Remove the display
PCB from the control PCB to measure the resistance.
When the indoor heat exchanger thermistor is soldered on the PCB, remove the thermistor and
measure the resistance.
Temperature (°C / °F)
Resistance (k
)
–20 / –4
197.8
–15 / 5
148.2
–10 / 14
112.1
–5 / 23
85.60
0 / 32
65.93
5 / 41
51.14
10 / 50
39.99
15 / 59
31.52
20 / 68
25.02
25 / 77
20.00
30 / 86
16.10
35 / 95
13.04
40 / 104
10.62
45 / 113
8.707
50 / 122
7.176
(R25°C (77°F) = 20 k
, B = 3950 K)
(k
Ω
)
150
100
50
–15
0
15
30
45
(R14467)
5
32
59
86
113
(˚C)
(˚F)
Tester
Resistance range
(R11906)
RTH1
Tester
(R3460)
Содержание FTXS30LVJU
Страница 8: ...SiUS091133 Table of Contents vii...
Страница 11: ...SiUS091133 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 FTXS Series 2 1 2 FDXS Series 4...
Страница 15: ...SiUS091133 5 Specifications Part 2 Specifications 1 Specifications 6 1 1 FTXS Series 6 1 2 FDXS Series 11...
Страница 164: ...SiUS091133 Check Service Diagnosis 154 15 18 class 24 30 36 class Power module R16697 R16073 Power module...
Страница 259: ...Indoor Unit FTXS30 36LVJU SiUS091133 249 Removal Procedure 6 Disconnect the connector Step Procedure Points R9558...
Страница 413: ...Wiring Diagrams SiUS091133 403 Appendix...