RXA42~50A unit
a
L803
b
L804
c
Measuring point
d
Measuring point
e
Measuring point
d
d
c
e
a
b
c
d
c
d
e
e
e
c
A
A
RXA42~50B unit
a
L803
b
L804
c
Measuring point
d
Measuring point
e
Measuring point
Is the resistance measurement correct? Action
Yes
Proceed with the next step.
No
4
Measure the inductance of the reactor using an LCR meter.
Result:
The inductance MUST be as follows:
Measuring points
Resistance
c‑d
88.5~101.5 µH