2
|
Components
Service manual
134
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
a
A
b
A
RXA42~50A unit
a
Reactor L803
b
Reactor L804
a
b
A
A
RXA42~50B unit
a
Reactor L803
b
Reactor L804
2
Remove the main PCB, see
108]. The reactor
measuring points are ONLY reachable on the back side of the main PCB.
3
Measure the resistance of the reactor using a low ohm multi meter.
Result:
The resistance MUST be as follows:
Measuring points
Resistance
c‑d
15~25 mΩ
e
152~228 mΩ